FabDigitFabDigit

Copper Alloy C93600 vs C95400

Copper Alloy · grade comparison

Copper Alloy C93600 and C95400 are both copper alloy grades. C95400 is the stronger of the two: yield strength 241 MPa (35 ksi) against 110 MPa (16 ksi) for C93600, about 119% more; tensile strength follows at 586 MPa (85 ksi) vs 207 MPa (30 ksi). In exchange, C93600 is the more ductile: elongation 15% versus 12% for C95400, and C95400 is harder (170 HB vs 60 HB). C95400 is lighter (7.45 g/cm³ vs 8.94 g/cm³ for C93600) and C95400 is stiffer (110 GPa vs 76 GPa). On the shop floor, C93600 machines more easily (excellent vs fair) and C95400 welds better (good vs not recommended).

C93600Choose it when the part is bent, formed or impact-loaded, or when the part is machined in volume.

C95400Choose it when strength drives the design, or when weight is the constraint.

C93600 vs C95400: properties

C93600C95400

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

76 GPa11 Msi
110 GPa16 Msi

Shear Modulus

28 GPa4.1 Msi
42 GPa6.1 Msi

Poisson's Ratio

0.34
0.32

Tensile Strength (Ultimate)

207 MPa30 ksi
586 MPa85 ksi

Yield Strength (0.2% offset)

110 MPa16 ksi
241 MPa35 ksi

Elongation at Break

15%
12%

Reduction in Area

12%
—

Shear Strength

150 MPa21.8 ksi
380 MPa55.1 ksi

Fatigue Strength (Endurance Limit)

70 MPa10.2 ksi
193 MPa28 ksi

Charpy V-Notch Impact (RT)

8 J5.9 ft·lbf
20 J14.8 ft·lbf

Hardness, Brinell

60 HB
170 HB

Hardness, Vickers

63 HV
—

Hardness, Rockwell B

—
87 HRB

Same in both: Bulk Modulus 105 GPa15.2 Msi

Physical

Density and transition temperatures.

Density

8.94 g/cm³0.32 lb/in³
7.45 g/cm³0.27 lb/in³

Melting Point (Solidus)

762°C1,404 °F
1,038°C1,900 °F

Liquidus Temperature

954°C1,749 °F
1,054°C1,929 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

47 W/m·K27.2 BTU/hr·ft·°F
58.6 W/m·K33.9 BTU/hr·ft·°F

Specific Heat Capacity

251 J/kg·K0.06 BTU/lb·°F
418 J/kg·K0.1 BTU/lb·°F

Thermal Expansion (CTE, 20–100 °C)

18.5 µm/m·K10.3 µin/in·°F
16.2 µm/m·K9 µin/in·°F

Latent Heat of Fusion

165 J/g70.9 BTU/lb
220 J/g94.6 BTU/lb

Max Service Temperature (continuous)

230°C446 °F
300°C572 °F

Min Service Temperature

-100°C-148 °F
-196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

11 % IACS
13 % IACS

Electrical Resistivity

1.57×10⁻⁷ Ω·m6.18 µΩ·in
1.33×10⁻⁷ Ω·m5.24 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

55 / 100
72 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.31 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

85 / 100
48 / 100

Machinability Rating (AISI 1212 = 100 %)

80%
60%

Weldability

10 / 100
60 / 100

Formability (cold)

10 / 100
20 / 100

Castability

85 / 100
78 / 100

Brazeability / Solderability

40 / 100
35 / 100

Polishability

55 / 100
70 / 100

Sustainability

Primary-production footprint per kilogram.

Embodied Water

320 L/kg38.3 gal/lb
250 L/kg30 gal/lb

Typical Recycled Content

75%
50%

Same in both: Embodied Energy (primary production) 55 MJ/kg23,646 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg

Common Calculations

Ratios derived from the values above.

Specific Strength (UTS / density)

23 kN·m/kg
79 kN·m/kg

Specific Stiffness (E / density)

8.5 MN·m/kg
14.8 MN·m/kg

Modulus of Resilience

80 kJ/m³
264 kJ/m³

Thermal Diffusivity

20.9 mm²/s
18.8 mm²/s

Thermal Shock Resistance Index

7
19

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC93600C95400

Manufacturing and finishing

CapabilityC93600C95400
Default conditionAs CastAs Cast
Relative cost$$$$$ Specialty$$$$$ Specialty
Min. machined wall0.8 mm0.8 mm
Best machined surfaceRa 1.6 µmRa 1.6 µm

Both are offered for CNC machining. Both take the same 9 finishes: Chrome Plating, Copper Plating, Electroless Nickel (EN), Electropolishing, Gold Plating, Nickel Plating, Painting, Silver Plating, Tin Plating.

C93600 vs C95400 — frequently asked

Is C95400 stronger than C93600?

Yes. C95400 has a typical yield strength of 241 MPa (35 ksi) against 110 MPa (16 ksi) for C93600 — about 119% more. Tensile strength is 586 MPa (85 ksi) vs 207 MPa (30 ksi).

Which is cheaper, C93600 or C95400?

Both sit in the same relative cost tier ($$$$$, specialty); the part price will be decided by machining time, tolerance and quantity rather than by the material.

Which is easier to machine, C93600 or C95400?

C93600. Its machinability rates excellent (85/100) against fair (48/100) for C95400; for welding the order is C95400 first (good, 60/100) then C93600 (not recommended, 10/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in C93600 and C95400 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.