FabDigitFabDigit

Copper Alloy C75400-H01 vs C75400-H04

Copper Alloy · C75400 temper comparison

C75400-H01 and C75400-H04 are two conditions of the same copper alloy grade, C75400: H01 (quarter hard) versus H04 (full hard). The chemistry is identical, so every difference below comes from the condition. C75400-H04 is the stronger of the two: yield strength 510 MPa (74 ksi) against 320 MPa (46.4 ksi) for C75400-H01, about 59% more; tensile strength follows at 585 MPa (84.8 ksi) vs 460 MPa (66.7 ksi). In exchange, C75400-H01 is the more ductile: elongation 20% versus 5% for C75400-H04, and C75400-H04 is harder (165 HB vs 118 HB). C75400-H01 runs hotter in service (220°C vs 180°C continuous).

C75400-H01Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C75400-H04Choose it when strength drives the design.

C75400-H01 vs C75400-H04: properties

C75400-H01C75400-H04

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

460 MPa66.7 ksi
585 MPa84.8 ksi

Yield Strength (0.2% offset)

320 MPa46.4 ksi
510 MPa74 ksi

Elongation at Break

20%
5%

Shear Strength

315 MPa45.7 ksi
365 MPa52.9 ksi

Fatigue Strength (Endurance Limit)

180 MPa26.1 ksi
205 MPa29.7 ksi

Hardness, Brinell

118 HB
165 HB

Hardness, Rockwell B

66 HRB
82 HRB

Same in both: Elastic (Young's) Modulus 125 GPa18.1 Msi · Shear Modulus 47 GPa6.8 Msi · Bulk Modulus 122 GPa17.7 Msi · Poisson's Ratio 0.33 · Hardness, Vickers 150 HV

Physical

Density and transition temperatures.

Same in both: Density 8.72 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,021°C1,870 °F · Liquidus Temperature 1,054°C1,929 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

220°C428 °F
180°C356 °F

Same in both: Thermal Conductivity 37 W/m·K21.4 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 16.2 µm/m·K9 µin/in·°F · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 6.5 % IACS · Electrical Resistivity 2.65×10⁻⁷ Ω·m10.4 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.27 V · Corrosion Resistance 66 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

30 / 100
32 / 100

Machinability Rating (AISI 1212 = 100 %)

20%
22%

Formability (cold)

65 / 100
38 / 100

Same in both: Weldability 45 / 100 · Brazeability / Solderability 80 / 100 · Polishability 88 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 78 MJ/kg33,534 BTU/lb · Embodied Carbon (primary production) 5.2 kg CO₂/kg · Embodied Water 260 L/kg31.2 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC75400

C75400-H01 vs C75400-H04 — frequently asked

Is C75400-H04 stronger than C75400-H01?

Yes. C75400-H04 has a typical yield strength of 510 MPa (74 ksi) against 320 MPa (46.4 ksi) for C75400-H01 — about 59% more. Tensile strength is 585 MPa (84.8 ksi) vs 460 MPa (66.7 ksi).

Which condition does FabDigit quote by default, H01 or H04?

H02 is the default C75400 condition in the FabDigit quote flow (neither H01 nor H04). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C75400-H01 over C75400-H04?

Pick C75400-H01 when the part is bent, formed or impact-loaded, or when the part sees heat. Pick C75400-H04 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C75400-H01 and C75400-H04 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.