C36600-H01 and C36600-O61 are two conditions of the same copper alloy grade, C36600: H01 (quarter hard) versus O61 (annealed). The chemistry is identical, so every difference below comes from the condition. C36600-H01 is the stronger of the two: yield strength 275 MPa (39.9 ksi) against 125 MPa (18.1 ksi) for C36600-O61, about 120% more; tensile strength follows at 420 MPa (60.9 ksi) vs 345 MPa (50 ksi). In exchange, C36600-O61 is the more ductile: elongation 50% versus 25% for C36600-H01, and C36600-H01 is harder (110 HB vs 70 HB). C36600-O61 runs hotter in service (200°C vs 150°C continuous).

C36600-H01Choose it when strength drives the design.

C36600-O61Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C36600-H01 vs C36600-O61: properties

C36600-H01C36600-O61

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

420 MPa60.9 ksi
345 MPa50 ksi

Yield Strength (0.2% offset)

275 MPa39.9 ksi
125 MPa18.1 ksi

Elongation at Break

25%
50%

Shear Strength

280 MPa40.6 ksi
240 MPa34.8 ksi

Fatigue Strength (Endurance Limit)

150 MPa21.8 ksi
125 MPa18.1 ksi

Hardness, Brinell

110 HB
70 HB

Hardness, Rockwell B

65 HRB
45 HRB

Same in both: Elastic (Young's) Modulus 105 GPa15.2 Msi · Shear Modulus 39 GPa5.7 Msi · Bulk Modulus 115 GPa16.7 Msi · Poisson's Ratio 0.35

Physical

Density and transition temperatures.

Same in both: Density 8.41 g/cm³0.3 lb/in³ · Melting Point (Solidus) 885°C1,625 °F · Liquidus Temperature 900°C1,652 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

121 W/m·K69.9 BTU/hr·ft·°F
123 W/m·K71.1 BTU/hr·ft·°F

Max Service Temperature (continuous)

150°C302 °F
200°C392 °F

Same in both: Specific Heat Capacity 375 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 20.8 µm/m·K11.6 µin/in·°F · Latent Heat of Fusion 160 J/g68.8 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

27 % IACS
28 % IACS

Electrical Resistivity

6.4×10⁻⁸ Ω·m2.52 µΩ·in
6.2×10⁻⁸ Ω·m2.44 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

50 / 100
57 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.28 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

62 / 100
55 / 100

Machinability Rating (AISI 1212 = 100 %)

62%
55%

Formability (cold)

22 / 100
40 / 100

Same in both: Weldability 40 / 100 · Brazeability / Solderability 80 / 100 · Polishability 75 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 62 MJ/kg26,655 BTU/lb · Embodied Carbon (primary production) 3.8 kg CO₂/kg · Embodied Water 220 L/kg26.4 gal/lb · Typical Recycled Content 55%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC36600

C36600-H01 vs C36600-O61 — frequently asked

Is C36600-H01 stronger than C36600-O61?

Yes. C36600-H01 has a typical yield strength of 275 MPa (39.9 ksi) against 125 MPa (18.1 ksi) for C36600-O61 — about 120% more. Tensile strength is 420 MPa (60.9 ksi) vs 345 MPa (50 ksi).

Which condition does FabDigit quote by default, H01 or O61?

M20 is the default C36600 condition in the FabDigit quote flow (neither H01 nor O61). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C36600-H01 or C36600-O61?

C36600-H01, by a small margin. Both rate good for machinability — 62/100 against 55/100 for C36600-O61.