FabDigitFabDigit

Copper Alloy C36600-M30 vs C36600-O61

Copper Alloy · C36600 temper comparison

C36600-M30 and C36600-O61 are two conditions of the same copper alloy grade, C36600: M30 (as hot extruded) versus O61 (annealed). The chemistry is identical, so every difference below comes from the condition. C36600-M30 is the stronger of the two: yield strength 145 MPa (21 ksi) against 125 MPa (18.1 ksi) for C36600-O61, about 16% more; tensile strength follows at 365 MPa (52.9 ksi) vs 345 MPa (50 ksi). In exchange, C36600-O61 is the more ductile: elongation 50% versus 40% for C36600-M30, and C36600-M30 is harder (80 HB vs 70 HB).

C36600-M30Choose it when strength drives the design.

C36600-O61Choose it when the part is bent, formed or impact-loaded.

C36600-M30 vs C36600-O61: properties

C36600-M30C36600-O61

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

365 MPa52.9 ksi
345 MPa50 ksi

Yield Strength (0.2% offset)

145 MPa21 ksi
125 MPa18.1 ksi

Elongation at Break

40%
50%

Shear Strength

255 MPa37 ksi
240 MPa34.8 ksi

Fatigue Strength (Endurance Limit)

135 MPa19.6 ksi
125 MPa18.1 ksi

Hardness, Brinell

80 HB
70 HB

Hardness, Rockwell B

55 HRB
45 HRB

Same in both: Elastic (Young's) Modulus 105 GPa15.2 Msi · Shear Modulus 39 GPa5.7 Msi · Bulk Modulus 115 GPa16.7 Msi · Poisson's Ratio 0.35

Physical

Density and transition temperatures.

Same in both: Density 8.41 g/cm³0.3 lb/in³ · Melting Point (Solidus) 885°C1,625 °F · Liquidus Temperature 900°C1,652 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 123 W/m·K71.1 BTU/hr·ft·°F · Specific Heat Capacity 375 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 20.8 µm/m·K11.6 µin/in·°F · Latent Heat of Fusion 160 J/g68.8 BTU/lb · Max Service Temperature (continuous) 200°C392 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 28 % IACS · Electrical Resistivity 6.2×10⁻⁸ Ω·m2.44 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

55 / 100
57 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.28 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

60 / 100
55 / 100

Machinability Rating (AISI 1212 = 100 %)

60%
55%

Formability (cold)

30 / 100
40 / 100

Same in both: Weldability 40 / 100 · Brazeability / Solderability 80 / 100 · Polishability 75 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 62 MJ/kg26,655 BTU/lb · Embodied Carbon (primary production) 3.8 kg CO₂/kg · Embodied Water 220 L/kg26.4 gal/lb · Typical Recycled Content 55%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC36600

C36600-M30 vs C36600-O61 — frequently asked

Is C36600-M30 stronger than C36600-O61?

Yes. C36600-M30 has a typical yield strength of 145 MPa (21 ksi) against 125 MPa (18.1 ksi) for C36600-O61 — about 16% more. Tensile strength is 365 MPa (52.9 ksi) vs 345 MPa (50 ksi).

Which condition does FabDigit quote by default, M30 or O61?

M20 is the default C36600 condition in the FabDigit quote flow (neither M30 nor O61). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C36600-M30 or C36600-O61?

C36600-M30, by a small margin. Both rate good for machinability — 60/100 against 55/100 for C36600-O61.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C36600-M30 and C36600-O61 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.