FabDigitFabDigit

Copper Alloy C36600-H01 vs C36600-H02

Copper Alloy · C36600 temper comparison

C36600-H01 and C36600-H02 are two conditions of the same copper alloy grade, C36600: H01 (quarter hard) versus H02 (half hard). The chemistry is identical, so every difference below comes from the condition. C36600-H02 is the stronger of the two: yield strength 350 MPa (50.8 ksi) against 275 MPa (39.9 ksi) for C36600-H01, about 27% more; tensile strength follows at 470 MPa (68.2 ksi) vs 420 MPa (60.9 ksi). In exchange, C36600-H01 is the more ductile: elongation 25% versus 15% for C36600-H02, and C36600-H02 is harder (130 HB vs 110 HB).

C36600-H01Choose it when the part is bent, formed or impact-loaded.

C36600-H02Choose it when strength drives the design.

C36600-H01 vs C36600-H02: properties

C36600-H01C36600-H02

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

420 MPa60.9 ksi
470 MPa68.2 ksi

Yield Strength (0.2% offset)

275 MPa39.9 ksi
350 MPa50.8 ksi

Elongation at Break

25%
15%

Shear Strength

280 MPa40.6 ksi
305 MPa44.2 ksi

Fatigue Strength (Endurance Limit)

150 MPa21.8 ksi
165 MPa23.9 ksi

Hardness, Brinell

110 HB
130 HB

Hardness, Rockwell B

65 HRB
75 HRB

Same in both: Elastic (Young's) Modulus 105 GPa15.2 Msi · Shear Modulus 39 GPa5.7 Msi · Bulk Modulus 115 GPa16.7 Msi · Poisson's Ratio 0.35

Physical

Density and transition temperatures.

Same in both: Density 8.41 g/cm³0.3 lb/in³ · Melting Point (Solidus) 885°C1,625 °F · Liquidus Temperature 900°C1,652 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 121 W/m·K69.9 BTU/hr·ft·°F · Specific Heat Capacity 375 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 20.8 µm/m·K11.6 µin/in·°F · Latent Heat of Fusion 160 J/g68.8 BTU/lb · Max Service Temperature (continuous) 150°C302 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 27 % IACS · Electrical Resistivity 6.4×10⁻⁸ Ω·m2.52 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

50 / 100
48 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.28 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

62 / 100
65 / 100

Machinability Rating (AISI 1212 = 100 %)

62%
65%

Formability (cold)

22 / 100
15 / 100

Same in both: Weldability 40 / 100 · Brazeability / Solderability 80 / 100 · Polishability 75 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 62 MJ/kg26,655 BTU/lb · Embodied Carbon (primary production) 3.8 kg CO₂/kg · Embodied Water 220 L/kg26.4 gal/lb · Typical Recycled Content 55%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC36600

C36600-H01 vs C36600-H02 — frequently asked

Is C36600-H02 stronger than C36600-H01?

Yes. C36600-H02 has a typical yield strength of 350 MPa (50.8 ksi) against 275 MPa (39.9 ksi) for C36600-H01 — about 27% more. Tensile strength is 470 MPa (68.2 ksi) vs 420 MPa (60.9 ksi).

Which condition does FabDigit quote by default, H01 or H02?

M20 is the default C36600 condition in the FabDigit quote flow (neither H01 nor H02). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C36600-H01 over C36600-H02?

Pick C36600-H01 when the part is bent, formed or impact-loaded. Pick C36600-H02 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C36600-H01 and C36600-H02 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.