Copper Alloy C36500-H01 vs C36500-M30
Copper Alloy · C36500 temper comparison
C36500-H01 and C36500-M30 are two conditions of the same copper alloy grade, C36500: H01 (quarter hard) versus M30 (as hot extruded). The chemistry is identical, so every difference below comes from the condition. C36500-H01 is the stronger of the two: yield strength 275 MPa (39.9 ksi) against 140 MPa (20.3 ksi) for C36500-M30, about 96% more; tensile strength follows at 415 MPa (60.2 ksi) vs 360 MPa (52.2 ksi). In exchange, C36500-M30 is the more ductile: elongation 45% versus 25% for C36500-H01, and C36500-H01 is harder (115 HB vs 78 HB). C36500-M30 runs hotter in service (200°C vs 150°C continuous).
C36500-H01Choose it when strength drives the design.
C36500-M30Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.
C36500-H01 vs C36500-M30: propertiesHow to read these bars
- One bar per material. A full bar is the highest value among all copper alloy grades in the FabDigit library; each bar is drawn as a share of that.
- The better value (by the usual engineering direction) is in bold. Rows with no direction — density, thermal conductivity — have no bold.
- Values are typical room-temperature figures for the condition named on each card.
- Confirm against the certified mill or resin datasheet before design release.
How to read these bars
- One bar per material. A full bar is the highest value among all copper alloy grades in the FabDigit library; each bar is drawn as a share of that.
- The better value (by the usual engineering direction) is in bold. Rows with no direction — density, thermal conductivity — have no bold.
- Values are typical room-temperature figures for the condition named on each card.
- Confirm against the certified mill or resin datasheet before design release.
Mechanical
Strength, stiffness, ductility and hardness at room temperature.
Tensile Strength (Ultimate)
Yield Strength (0.2% offset)
Elongation at Break
Shear Strength
Fatigue Strength (Endurance Limit)
Hardness, Brinell
Hardness, Rockwell B
Same in both: Elastic (Young's) Modulus 105 GPa15.2 Msi · Shear Modulus 39 GPa5.7 Msi · Bulk Modulus 112 GPa16.2 Msi · Poisson's Ratio 0.35
Physical
Density and transition temperatures.
Same in both: Density 8.41 g/cm³0.3 lb/in³ · Melting Point (Solidus) 885°C1,625 °F · Liquidus Temperature 900°C1,652 °F
Thermal
How each material carries heat and how hot it can run.
Thermal Conductivity
Max Service Temperature (continuous)
Same in both: Specific Heat Capacity 375 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 20.8 µm/m·K11.6 µin/in·°F · Latent Heat of Fusion 160 J/g68.8 BTU/lb · Min Service Temperature -196°C-321 °F
Electrical
Conductivity and insulation.
Electrical Conductivity
Electrical Resistivity
Chemical & Environmental
Corrosion and environmental resistance (0–100 scores).
Corrosion Resistance
Same in both: Galvanic Potential (seawater, vs SCE) -0.28 V
Manufacturability
FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.
Formability (cold)
Same in both: Machinability 65 / 100 · Machinability Rating (AISI 1212 = 100 %) 60% · Weldability 25 / 100 · Brazeability / Solderability 80 / 100 · Polishability 75 / 100
Sustainability
Primary-production footprint per kilogram.
Same in both: Embodied Energy (primary production) 58 MJ/kg24,936 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 250 L/kg30 gal/lb · Typical Recycled Content 50%
Strength versus weight
Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.
C36500-H01 vs C36500-M30 — frequently asked
Is C36500-H01 stronger than C36500-M30?
Yes. C36500-H01 has a typical yield strength of 275 MPa (39.9 ksi) against 140 MPa (20.3 ksi) for C36500-M30 — about 96% more. Tensile strength is 415 MPa (60.2 ksi) vs 360 MPa (52.2 ksi).
Which condition does FabDigit quote by default, H01 or M30?
M20 is the default C36500 condition in the FabDigit quote flow (neither H01 nor M30). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.
When should I choose C36500-H01 over C36500-M30?
Pick C36500-H01 when strength drives the design. Pick C36500-M30 when the part is bent, formed or impact-loaded, or when the part sees heat.
Ready to make it?
Upload a CAD file and FabDigit prices the part in C36500-H01 and C36500-M30 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.
Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.