FabDigitFabDigit

Copper Alloy C36500-H01 vs C36500-H02

Copper Alloy · C36500 temper comparison

C36500-H01 and C36500-H02 are two conditions of the same copper alloy grade, C36500: H01 (quarter hard) versus H02 (half hard). The chemistry is identical, so every difference below comes from the condition. C36500-H02 is the stronger of the two: yield strength 345 MPa (50 ksi) against 275 MPa (39.9 ksi) for C36500-H01, about 25% more; tensile strength follows at 470 MPa (68.2 ksi) vs 415 MPa (60.2 ksi). In exchange, C36500-H01 is the more ductile: elongation 25% versus 15% for C36500-H02, and C36500-H02 is harder (140 HB vs 115 HB).

C36500-H01Choose it when the part is bent, formed or impact-loaded.

C36500-H02Choose it when strength drives the design.

C36500-H01 vs C36500-H02: properties

C36500-H01C36500-H02

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

415 MPa60.2 ksi
470 MPa68.2 ksi

Yield Strength (0.2% offset)

275 MPa39.9 ksi
345 MPa50 ksi

Elongation at Break

25%
15%

Shear Strength

260 MPa37.7 ksi
290 MPa42.1 ksi

Fatigue Strength (Endurance Limit)

140 MPa20.3 ksi
150 MPa21.8 ksi

Hardness, Brinell

115 HB
140 HB

Hardness, Rockwell B

68 HRB
78 HRB

Same in both: Elastic (Young's) Modulus 105 GPa15.2 Msi · Shear Modulus 39 GPa5.7 Msi · Bulk Modulus 112 GPa16.2 Msi · Poisson's Ratio 0.35

Physical

Density and transition temperatures.

Same in both: Density 8.41 g/cm³0.3 lb/in³ · Melting Point (Solidus) 885°C1,625 °F · Liquidus Temperature 900°C1,652 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

121 W/m·K69.9 BTU/hr·ft·°F
120 W/m·K69.3 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 375 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 20.8 µm/m·K11.6 µin/in·°F · Latent Heat of Fusion 160 J/g68.8 BTU/lb · Max Service Temperature (continuous) 150°C302 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 25 % IACS · Electrical Resistivity 6.9×10⁻⁸ Ω·m2.72 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

53 / 100
52 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.28 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

65 / 100
70 / 100

Machinability Rating (AISI 1212 = 100 %)

60%
65%

Formability (cold)

35 / 100
25 / 100

Same in both: Weldability 25 / 100 · Brazeability / Solderability 80 / 100 · Polishability 75 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 58 MJ/kg24,936 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 250 L/kg30 gal/lb · Typical Recycled Content 50%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC36500

C36500-H01 vs C36500-H02 — frequently asked

Is C36500-H02 stronger than C36500-H01?

Yes. C36500-H02 has a typical yield strength of 345 MPa (50 ksi) against 275 MPa (39.9 ksi) for C36500-H01 — about 25% more. Tensile strength is 470 MPa (68.2 ksi) vs 415 MPa (60.2 ksi).

Which condition does FabDigit quote by default, H01 or H02?

M20 is the default C36500 condition in the FabDigit quote flow (neither H01 nor H02). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C36500-H01 or C36500-H02?

C36500-H02. Its machinability rates very good (70/100) against good (65/100) for C36500-H01.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C36500-H01 and C36500-H02 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.