FabDigitFabDigit

Copper Alloy C17450-TB00 vs C17450-TM02

Copper Alloy · C17450 temper comparison

C17450-TB00 and C17450-TM02 are two conditions of the same copper alloy grade, C17450: TB00 (solution heat treated) versus TM02 (mill hardened, half hard). The chemistry is identical, so every difference below comes from the condition. C17450-TM02 is the stronger of the two: yield strength 515 MPa (74.7 ksi) against 170 MPa (24.7 ksi) for C17450-TB00, about 3.0 times as much; tensile strength follows at 620 MPa (89.9 ksi) vs 330 MPa (47.9 ksi). In exchange, C17450-TB00 is the more ductile: elongation 35% versus 15% for C17450-TM02, and C17450-TB00 is harder (200 HB vs 175 HB). C17450-TM02 conducts heat better (220 W/m·K vs 110 W/m·K).

C17450-TB00Choose it when the part is bent, formed or impact-loaded.

C17450-TM02Choose it when strength drives the design.

C17450-TB00 vs C17450-TM02: properties

C17450-TB00C17450-TM02

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

330 MPa47.9 ksi
620 MPa89.9 ksi

Yield Strength (0.2% offset)

170 MPa24.7 ksi
515 MPa74.7 ksi

Elongation at Break

35%
15%

Shear Strength

420 MPa60.9 ksi
380 MPa55.1 ksi

Fatigue Strength (Endurance Limit)

260 MPa37.7 ksi
240 MPa34.8 ksi

Hardness, Brinell

200 HB
175 HB

Hardness, Rockwell B

45 HRB
88 HRB

Hardness, Vickers

90 HV
185 HV

Same in both: Elastic (Young's) Modulus 138 GPa20 Msi · Shear Modulus 53 GPa7.7 Msi · Bulk Modulus 115 GPa16.7 Msi · Poisson's Ratio 0.3

Physical

Density and transition temperatures.

Same in both: Density 8.8 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,030°C1,886 °F · Liquidus Temperature 1,070°C1,958 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

110 W/m·K63.6 BTU/hr·ft·°F
220 W/m·K127 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 420 J/kg·K0.1 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17.6 µm/m·K9.8 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Max Service Temperature (continuous) 200°C392 °F · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

25 % IACS
53 % IACS

Electrical Resistivity

6.9×10⁻⁸ Ω·m2.72 µΩ·in
3.25×10⁻⁸ Ω·m1.28 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.2 V · Corrosion Resistance 58 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

35 / 100
33 / 100

Machinability Rating (AISI 1212 = 100 %)

25%
18%

Formability (cold)

85 / 100
65 / 100

Same in both: Weldability 55 / 100 · Brazeability / Solderability 75 / 100 · Polishability 78 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 75 MJ/kg32,244 BTU/lb · Embodied Carbon (primary production) 5.2 kg CO₂/kg · Embodied Water 250 L/kg30 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC17450

C17450-TB00 vs C17450-TM02 — frequently asked

Is C17450-TM02 stronger than C17450-TB00?

Yes. C17450-TM02 has a typical yield strength of 515 MPa (74.7 ksi) against 170 MPa (24.7 ksi) for C17450-TB00 — about 3.0 times as much. Tensile strength is 620 MPa (89.9 ksi) vs 330 MPa (47.9 ksi).

Which condition does FabDigit quote by default, TB00 or TM02?

TM04 is the default C17450 condition in the FabDigit quote flow (neither TB00 nor TM02). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C17450-TB00 over C17450-TM02?

Pick C17450-TB00 when the part is bent, formed or impact-loaded. Pick C17450-TM02 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C17450-TB00 and C17450-TM02 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.