FabDigitFabDigit

Copper Alloy C17450-TB00 vs C17450-TM06

Copper Alloy · C17450 temper comparison

C17450-TB00 and C17450-TM06 are two conditions of the same copper alloy grade, C17450: TB00 (solution heat treated) versus TM06 (mill hardened, extra hard). The chemistry is identical, so every difference below comes from the condition. C17450-TM06 is the stronger of the two: yield strength 655 MPa (95 ksi) against 170 MPa (24.7 ksi) for C17450-TB00, about 3.9 times as much; tensile strength follows at 760 MPa (110 ksi) vs 330 MPa (47.9 ksi). In exchange, C17450-TB00 is the more ductile: elongation 35% versus 10% for C17450-TM06, and C17450-TM06 is harder (222 HB vs 200 HB). C17450-TM06 conducts heat better (200 W/m·K vs 110 W/m·K).

C17450-TB00Choose it when the part is bent, formed or impact-loaded.

C17450-TM06Choose it when strength drives the design.

C17450-TB00 vs C17450-TM06: properties

C17450-TB00C17450-TM06

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

330 MPa47.9 ksi
760 MPa110 ksi

Yield Strength (0.2% offset)

170 MPa24.7 ksi
655 MPa95 ksi

Elongation at Break

35%
10%

Shear Strength

420 MPa60.9 ksi
450 MPa65.3 ksi

Fatigue Strength (Endurance Limit)

260 MPa37.7 ksi
275 MPa39.9 ksi

Hardness, Brinell

200 HB
222 HB

Hardness, Rockwell B

45 HRB
96 HRB

Hardness, Vickers

90 HV
235 HV

Same in both: Elastic (Young's) Modulus 138 GPa20 Msi · Shear Modulus 53 GPa7.7 Msi · Bulk Modulus 115 GPa16.7 Msi · Poisson's Ratio 0.3

Physical

Density and transition temperatures.

Same in both: Density 8.8 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,030°C1,886 °F · Liquidus Temperature 1,070°C1,958 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

110 W/m·K63.6 BTU/hr·ft·°F
200 W/m·K116 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 420 J/kg·K0.1 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17.6 µm/m·K9.8 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Max Service Temperature (continuous) 200°C392 °F · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

25 % IACS
48 % IACS

Electrical Resistivity

6.9×10⁻⁸ Ω·m2.72 µΩ·in
3.59×10⁻⁸ Ω·m1.41 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.2 V · Corrosion Resistance 58 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

35 / 100
38 / 100

Machinability Rating (AISI 1212 = 100 %)

25%
22%

Weldability

55 / 100
52 / 100

Formability (cold)

85 / 100
45 / 100

Same in both: Brazeability / Solderability 75 / 100 · Polishability 78 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 75 MJ/kg32,244 BTU/lb · Embodied Carbon (primary production) 5.2 kg CO₂/kg · Embodied Water 250 L/kg30 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC17450

C17450-TB00 vs C17450-TM06 — frequently asked

Is C17450-TM06 stronger than C17450-TB00?

Yes. C17450-TM06 has a typical yield strength of 655 MPa (95 ksi) against 170 MPa (24.7 ksi) for C17450-TB00 — about 3.9 times as much. Tensile strength is 760 MPa (110 ksi) vs 330 MPa (47.9 ksi).

Which condition does FabDigit quote by default, TB00 or TM06?

TM04 is the default C17450 condition in the FabDigit quote flow (neither TB00 nor TM06). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C17450-TB00 over C17450-TM06?

Pick C17450-TB00 when the part is bent, formed or impact-loaded. Pick C17450-TM06 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C17450-TB00 and C17450-TM06 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.