FabDigitFabDigit

Copper Alloy C17300-TD02 vs C17300-TH01

Copper Alloy · C17300 temper comparison

C17300-TD02 and C17300-TH01 are two conditions of the same copper alloy grade, C17300: TD02 (solution heat treated and cold worked, half hard) versus TH01 (TD01 and precipitation hardened). The chemistry is identical, so every difference below comes from the condition. C17300-TH01 is the stronger of the two: yield strength 1,105 MPa (160 ksi) against 550 MPa (79.8 ksi) for C17300-TD02, about 101% more; tensile strength follows at 1,240 MPa (180 ksi) vs 640 MPa (92.8 ksi). In exchange, C17300-TD02 is the more ductile: elongation 15% versus 4% for C17300-TH01, and C17300-TH01 is harder (375 HB vs 190 HB). C17300-TH01 runs hotter in service (200°C vs 100°C continuous) and C17300-TH01 conducts heat better (130 W/m·K vs 105 W/m·K).

C17300-TD02Choose it when the part is bent, formed or impact-loaded.

C17300-TH01Choose it when strength drives the design, or when the part sees heat.

C17300-TD02 vs C17300-TH01: properties

C17300-TD02C17300-TH01

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

128 GPa18.6 Msi
131 GPa19 Msi

Tensile Strength (Ultimate)

640 MPa92.8 ksi
1,240 MPa180 ksi

Yield Strength (0.2% offset)

550 MPa79.8 ksi
1,105 MPa160 ksi

Elongation at Break

15%
4%

Reduction in Area

40%
15%

Shear Strength

420 MPa60.9 ksi
750 MPa109 ksi

Fatigue Strength (Endurance Limit)

250 MPa36.3 ksi
340 MPa49.3 ksi

Hardness, Brinell

190 HB
375 HB

Hardness, Rockwell B

92 HRB
60 HRB

Hardness, Vickers

200 HV
392 HV

Same in both: Shear Modulus 50 GPa7.3 Msi · Bulk Modulus 115 GPa16.7 Msi · Poisson's Ratio 0.3

Physical

Density and transition temperatures.

Same in both: Density 8.26 g/cm³0.3 lb/in³ · Melting Point (Solidus) 865°C1,589 °F · Liquidus Temperature 980°C1,796 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

105 W/m·K60.7 BTU/hr·ft·°F
130 W/m·K75.1 BTU/hr·ft·°F

Max Service Temperature (continuous)

100°C212 °F
200°C392 °F

Same in both: Specific Heat Capacity 420 J/kg·K0.1 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17.5 µm/m·K9.7 µin/in·°F · Latent Heat of Fusion 200 J/g86 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

18 % IACS
23 % IACS

Electrical Resistivity

9.6×10⁻⁸ Ω·m3.78 µΩ·in
7.5×10⁻⁸ Ω·m2.95 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.23 V · Corrosion Resistance 62 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

60 / 100
58 / 100

Weldability

15 / 100
12 / 100

Formability (cold)

40 / 100
10 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 60% · Castability 45 / 100 · Brazeability / Solderability 60 / 100 · Polishability 75 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 120 MJ/kg51,591 BTU/lb · Embodied Carbon (primary production) 7.5 kg CO₂/kg · Embodied Water 350 L/kg41.9 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC17300

C17300-TD02 vs C17300-TH01 — frequently asked

Is C17300-TH01 stronger than C17300-TD02?

Yes. C17300-TH01 has a typical yield strength of 1,105 MPa (160 ksi) against 550 MPa (79.8 ksi) for C17300-TD02 — about 101% more. Tensile strength is 1,240 MPa (180 ksi) vs 640 MPa (92.8 ksi).

Which condition does FabDigit quote by default, TD02 or TH01?

A is the default C17300 condition in the FabDigit quote flow (neither TD02 nor TH01). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C17300-TD02 over C17300-TH01?

Pick C17300-TD02 when the part is bent, formed or impact-loaded. Pick C17300-TH01 when strength drives the design, or when the part sees heat.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C17300-TD02 and C17300-TH01 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.