FabDigitFabDigit

Copper Alloy C17300-TD02 vs C17300-TF00

Copper Alloy · C17300 temper comparison

C17300-TD02 and C17300-TF00 are two conditions of the same copper alloy grade, C17300: TD02 (solution heat treated and cold worked, half hard) versus TF00 (solution heat treated and precipitation hardened). The chemistry is identical, so every difference below comes from the condition. C17300-TF00 is the stronger of the two: yield strength 1,035 MPa (150 ksi) against 550 MPa (79.8 ksi) for C17300-TD02, about 88% more; tensile strength follows at 1,210 MPa (175 ksi) vs 640 MPa (92.8 ksi). In exchange, C17300-TD02 is the more ductile: elongation 15% versus 5% for C17300-TF00, and C17300-TF00 is harder (360 HB vs 190 HB). C17300-TF00 runs hotter in service (200°C vs 100°C continuous) and C17300-TF00 conducts electricity better (24 % IACS vs 18 % IACS). On the shop floor, C17300-TF00 welds better (25 vs 15 out of 100).

C17300-TD02Choose it when the part is bent, formed or impact-loaded.

C17300-TF00Choose it when strength drives the design, or when the part sees heat.

C17300-TD02 vs C17300-TF00: properties

C17300-TD02C17300-TF00

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

128 GPa18.6 Msi
130 GPa18.9 Msi

Bulk Modulus

115 GPa16.7 Msi
108 GPa15.7 Msi

Tensile Strength (Ultimate)

640 MPa92.8 ksi
1,210 MPa175 ksi

Yield Strength (0.2% offset)

550 MPa79.8 ksi
1,035 MPa150 ksi

Elongation at Break

15%
5%

Reduction in Area

40%
50%

Shear Strength

420 MPa60.9 ksi
760 MPa110 ksi

Fatigue Strength (Endurance Limit)

250 MPa36.3 ksi
275 MPa39.9 ksi

Hardness, Brinell

190 HB
360 HB

Hardness, Rockwell B

92 HRB
60 HRB

Hardness, Vickers

200 HV
385 HV

Same in both: Shear Modulus 50 GPa7.3 Msi · Poisson's Ratio 0.3

Physical

Density and transition temperatures.

Same in both: Density 8.26 g/cm³0.3 lb/in³ · Melting Point (Solidus) 865°C1,589 °F · Liquidus Temperature 980°C1,796 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

105 W/m·K60.7 BTU/hr·ft·°F
115 W/m·K66.4 BTU/hr·ft·°F

Max Service Temperature (continuous)

100°C212 °F
200°C392 °F

Same in both: Specific Heat Capacity 420 J/kg·K0.1 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17.5 µm/m·K9.7 µin/in·°F · Latent Heat of Fusion 200 J/g86 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

18 % IACS
24 % IACS

Electrical Resistivity

9.6×10⁻⁸ Ω·m3.78 µΩ·in
7.2×10⁻⁸ Ω·m2.83 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Galvanic Potential (seawater, vs SCE)

-0.23 V
-0.2 V

Corrosion Resistance

62 / 100
65 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

60 / 100
55 / 100

Machinability Rating (AISI 1212 = 100 %)

60%
55%

Weldability

15 / 100
25 / 100

Formability (cold)

40 / 100
15 / 100

Brazeability / Solderability

60 / 100
55 / 100

Polishability

75 / 100
80 / 100

Same in both: Castability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Embodied Energy (primary production)

120 MJ/kg51,591 BTU/lb
110 MJ/kg47,292 BTU/lb

Typical Recycled Content

35%
30%

Same in both: Embodied Carbon (primary production) 7.5 kg CO₂/kg · Embodied Water 350 L/kg41.9 gal/lb

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC17300

C17300-TD02 vs C17300-TF00 — frequently asked

Is C17300-TF00 stronger than C17300-TD02?

Yes. C17300-TF00 has a typical yield strength of 1,035 MPa (150 ksi) against 550 MPa (79.8 ksi) for C17300-TD02 — about 88% more. Tensile strength is 1,210 MPa (175 ksi) vs 640 MPa (92.8 ksi).

Which condition does FabDigit quote by default, TD02 or TF00?

A is the default C17300 condition in the FabDigit quote flow (neither TD02 nor TF00). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C17300-TD02 or C17300-TF00?

C17300-TD02, by a small margin. Both rate good for machinability — 60/100 against 55/100 for C17300-TF00; for welding the order is C17300-TF00 first (poor, 25/100) then C17300-TD02 (poor, 15/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in C17300-TD02 and C17300-TF00 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.