FabDigitFabDigit

Copper Alloy C10200 vs C16200

Copper Alloy · grade comparison

Copper Alloy C10200 and C16200 are both copper alloy grades. C16200 is the stronger of the two: yield strength 395 MPa (57.3 ksi) against 69 MPa (10 ksi) for C10200, about 5.7 times as much; tensile strength follows at 435 MPa (63.1 ksi) vs 221 MPa (32.1 ksi). In exchange, C10200 is the more ductile: elongation 45% versus 8% for C16200, and C16200 is harder (115 HB vs 45 HB). C10200 runs hotter in service (250°C vs 200°C continuous) and C10200 conducts heat better (391 W/m·K vs 350 W/m·K). On the shop floor, C10200 welds better (good vs fair).

C10200Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C16200Choose it when strength drives the design.

C10200 vs C16200: properties

C10200C16200

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

221 MPa32.1 ksi
435 MPa63.1 ksi

Yield Strength (0.2% offset)

69 MPa10 ksi
395 MPa57.3 ksi

Elongation at Break

45%
8%

Reduction in Area

75%
—

Shear Strength

152 MPa22 ksi
265 MPa38.4 ksi

Fatigue Strength (Endurance Limit)

76 MPa11 ksi
170 MPa24.7 ksi

Hardness, Brinell

45 HB
115 HB

Hardness, Vickers

50 HV
120 HV

Hardness, Rockwell B

—
65 HRB

Same in both: Elastic (Young's) Modulus 117 GPa17 Msi · Shear Modulus 44 GPa6.4 Msi · Bulk Modulus 140 GPa20.3 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Melting Point (Solidus)

1,083°C1,981 °F
1,030°C1,886 °F

Liquidus Temperature

1,083°C1,981 °F
1,076°C1,969 °F

Same in both: Density 8.94 g/cm³0.32 lb/in³

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

391 W/m·K226 BTU/hr·ft·°F
350 W/m·K202 BTU/hr·ft·°F

Thermal Expansion (CTE, 20–100 °C)

16.9 µm/m·K9.4 µin/in·°F
17 µm/m·K9.4 µin/in·°F

Max Service Temperature (continuous)

250°C482 °F
200°C392 °F

Min Service Temperature

-253°C-423 °F
-200°C-328 °F

Same in both: Specific Heat Capacity 385 J/kg·K0.09 BTU/lb·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb

Electrical

Conductivity and insulation.

Electrical Conductivity

101 % IACS
87 % IACS

Electrical Resistivity

1.71×10⁻⁸ Ω·m0.672 µΩ·in
1.98×10⁻⁸ Ω·m0.78 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V · Corrosion Resistance 70 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

22 / 100
25 / 100

Machinability Rating (AISI 1212 = 100 %)

18%
20%

Weldability

65 / 100
40 / 100

Formability (cold)

98 / 100
40 / 100

Castability

35 / 100
—

Brazeability / Solderability

97 / 100
85 / 100

Polishability

80 / 100
70 / 100

Sustainability

Primary-production footprint per kilogram.

Embodied Water

300 L/kg35.9 gal/lb
250 L/kg30 gal/lb

Typical Recycled Content

20%
30%

Same in both: Embodied Energy (primary production) 57 MJ/kg24,506 BTU/lb · Embodied Carbon (primary production) 3.8 kg CO₂/kg

Common Calculations

Ratios derived from the values above.

Specific Strength (UTS / density)

25 kN·m/kg
49 kN·m/kg

Modulus of Resilience

20 kJ/m³
667 kJ/m³

Thermal Diffusivity

113.6 mm²/s
101.7 mm²/s

Thermal Shock Resistance Index

44
77

Same in both: Specific Stiffness (E / density) 13.1 MN·m/kg

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC10200C16200

Manufacturing and finishing

CapabilityC10200C16200
CNC machiningYes—
Sheet metalYes—
Default conditionO—
Relative cost$$$$ High$$$$ High
Min. machined wall0.8 mm—
Best machined surfaceRa 1.6 µm—
Chrome PlatingYes—
ElectropolishingYes—
Nickel PlatingYes—
PaintingYes—
Tin PlatingYes—

They share 4 finishes: Copper Plating, Electroless Nickel (EN), Gold Plating, Silver Plating.

C10200 vs C16200 — frequently asked

Is C16200 stronger than C10200?

Yes. C16200 has a typical yield strength of 395 MPa (57.3 ksi) against 69 MPa (10 ksi) for C10200 — about 5.7 times as much. Tensile strength is 435 MPa (63.1 ksi) vs 221 MPa (32.1 ksi).

Which is cheaper, C10200 or C16200?

Both sit in the same relative cost tier ($$$$, high); the part price will be decided by machining time, tolerance and quantity rather than by the material.

Which welds better, C10200 or C16200?

C10200. Its weldability rates good (65/100) against fair (40/100) for C16200.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C10200 and C16200 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.