FabDigitFabDigit

Copper Alloy C10200 vs C11100

Copper Alloy · grade comparison

Copper Alloy C10200 and C11100 are both copper alloy grades. C11100 is the stronger of the two: yield strength 340 MPa (49.3 ksi) against 69 MPa (10 ksi) for C10200, about 4.9 times as much; tensile strength follows at 400 MPa (58 ksi) vs 221 MPa (32.1 ksi). In exchange, C10200 is the more ductile: elongation 45% versus 3% for C11100, and C11100 is harder (100 HB vs 45 HB). On the shop floor, C10200 welds better (good vs poor).

C10200Choose it when the part is bent, formed or impact-loaded, or when it will be welded.

C11100Choose it when strength drives the design.

C10200 vs C11100: properties

C10200C11100

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

221 MPa32.1 ksi
400 MPa58 ksi

Yield Strength (0.2% offset)

69 MPa10 ksi
340 MPa49.3 ksi

Elongation at Break

45%
3%

Reduction in Area

75%
—

Shear Strength

152 MPa22 ksi
200 MPa29 ksi

Fatigue Strength (Endurance Limit)

76 MPa11 ksi
115 MPa16.7 ksi

Hardness, Brinell

45 HB
100 HB

Hardness, Vickers

50 HV
—

Charpy V-Notch Impact (RT)

—
40 J29.5 ft·lbf

Hardness, Rockwell B

—
42 HRB

Same in both: Elastic (Young's) Modulus 117 GPa17 Msi · Shear Modulus 44 GPa6.4 Msi · Bulk Modulus 140 GPa20.3 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Melting Point (Solidus)

1,083°C1,981 °F
1,065°C1,949 °F

Same in both: Density 8.94 g/cm³0.32 lb/in³ · Liquidus Temperature 1,083°C1,981 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

391 W/m·K226 BTU/hr·ft·°F
385 W/m·K222 BTU/hr·ft·°F

Thermal Expansion (CTE, 20–100 °C)

16.9 µm/m·K9.4 µin/in·°F
17.7 µm/m·K9.8 µin/in·°F

Min Service Temperature

-253°C-423 °F
-250°C-418 °F

Same in both: Specific Heat Capacity 385 J/kg·K0.09 BTU/lb·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Max Service Temperature (continuous) 250°C482 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

101 % IACS
97 % IACS

Electrical Resistivity

1.71×10⁻⁸ Ω·m0.672 µΩ·in
1.78×10⁻⁸ Ω·m0.701 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Galvanic Potential (seawater, vs SCE)

-0.25 V
-0.22 V

Corrosion Resistance

70 / 100
60 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

22 / 100
30 / 100

Machinability Rating (AISI 1212 = 100 %)

18%
20%

Weldability

65 / 100
30 / 100

Formability (cold)

98 / 100
40 / 100

Castability

35 / 100
30 / 100

Brazeability / Solderability

97 / 100
95 / 100

Same in both: Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Embodied Carbon (primary production)

3.8 kg CO₂/kg
3.5 kg CO₂/kg

Embodied Water

300 L/kg35.9 gal/lb
150 L/kg18 gal/lb

Typical Recycled Content

20%
25%

Same in both: Embodied Energy (primary production) 57 MJ/kg24,506 BTU/lb

Common Calculations

Ratios derived from the values above.

Specific Strength (UTS / density)

25 kN·m/kg
45 kN·m/kg

Modulus of Resilience

20 kJ/m³
494 kJ/m³

Thermal Diffusivity

113.6 mm²/s
111.9 mm²/s

Thermal Shock Resistance Index

44
74

Same in both: Specific Stiffness (E / density) 13.1 MN·m/kg

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC10200C11100

Manufacturing and finishing

CapabilityC10200C11100
CNC machiningYes—
Sheet metalYes—
Default conditionO—
Relative cost$$$$ High$$$$ High
Min. machined wall0.8 mm—
Best machined surfaceRa 1.6 µm—
Chrome PlatingYes—
ElectropolishingYes—
Nickel PlatingYes—
PaintingYes—
Tin PlatingYes—

They share 4 finishes: Copper Plating, Electroless Nickel (EN), Gold Plating, Silver Plating.

C10200 vs C11100 — frequently asked

Is C11100 stronger than C10200?

Yes. C11100 has a typical yield strength of 340 MPa (49.3 ksi) against 69 MPa (10 ksi) for C10200 — about 4.9 times as much. Tensile strength is 400 MPa (58 ksi) vs 221 MPa (32.1 ksi).

Which is cheaper, C10200 or C11100?

Both sit in the same relative cost tier ($$$$, high); the part price will be decided by machining time, tolerance and quantity rather than by the material.

Which is easier to machine, C10200 or C11100?

C11100, by a small margin. Both rate poor for machinability — 30/100 against 22/100 for C10200; for welding the order is C10200 first (good, 65/100) then C11100 (poor, 30/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in C10200 and C11100 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.