FabDigitFabDigit

Copper Alloy C10100-H02 vs C10100-O

Copper Alloy · C10100 temper comparison

C10100-H02 and C10100-O are two conditions of the same copper alloy grade, C10100: H02 (half hard) versus O (annealed). The chemistry is identical, so every difference below comes from the condition. C10100-H02 is the stronger of the two: yield strength 250 MPa (36.3 ksi) against 69 MPa (10 ksi) for C10100-O, about 3.6 times as much; tensile strength follows at 295 MPa (42.8 ksi) vs 235 MPa (34.1 ksi). In exchange, C10100-O is the more ductile: elongation 45% versus 14% for C10100-H02, and C10100-H02 is harder (80 HB vs 45 HB). C10100-O runs hotter in service (200°C vs 150°C continuous). On the shop floor, C10100-H02 machines more easily (28 vs 18 out of 100).

C10100-H02Choose it when strength drives the design, or when the part is machined in volume.

C10100-OChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C10100-H02 vs C10100-O: properties

C10100-H02C10100-O

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

295 MPa42.8 ksi
235 MPa34.1 ksi

Yield Strength (0.2% offset)

250 MPa36.3 ksi
69 MPa10 ksi

Elongation at Break

14%
45%

Shear Strength

185 MPa26.8 ksi
152 MPa22 ksi

Hardness, Brinell

80 HB
45 HB

Hardness, Vickers

85 HV
50 HV

Same in both: Elastic (Young's) Modulus 117 GPa17 Msi · Shear Modulus 44 GPa6.4 Msi · Bulk Modulus 140 GPa20.3 Msi · Poisson's Ratio 0.34 · Reduction in Area 75% · Fatigue Strength (Endurance Limit) 76 MPa11 ksi

Physical

Density and transition temperatures.

Same in both: Density 8.94 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,083°C1,981 °F · Liquidus Temperature 1,083°C1,981 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

387 W/m·K224 BTU/hr·ft·°F
391 W/m·K226 BTU/hr·ft·°F

Max Service Temperature (continuous)

150°C302 °F
200°C392 °F

Same in both: Specific Heat Capacity 385 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17.7 µm/m·K9.8 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Min Service Temperature -253°C-423 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

98 % IACS
101 % IACS

Electrical Resistivity

1.76×10⁻⁸ Ω·m0.693 µΩ·in
1.71×10⁻⁸ Ω·m0.672 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.24 V · Corrosion Resistance 58 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

28 / 100
18 / 100

Machinability Rating (AISI 1212 = 100 %)

22%
20%

Formability (cold)

60 / 100
95 / 100

Same in both: Weldability 70 / 100 · Brazeability / Solderability 95 / 100 · Polishability 85 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 60 MJ/kg25,795 BTU/lb · Embodied Carbon (primary production) 3.8 kg CO₂/kg · Embodied Water 250 L/kg30 gal/lb · Typical Recycled Content 5%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC10100

C10100-H02 vs C10100-O — frequently asked

Is C10100-H02 stronger than C10100-O?

Yes. C10100-H02 has a typical yield strength of 250 MPa (36.3 ksi) against 69 MPa (10 ksi) for C10100-O — about 3.6 times as much. Tensile strength is 295 MPa (42.8 ksi) vs 235 MPa (34.1 ksi).

Which condition does FabDigit quote by default, H02 or O?

O is the default C10100 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C10100-H02 or C10100-O?

C10100-H02, by a small margin. Both rate poor for machinability — 28/100 against 18/100 for C10100-O.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C10100-H02 and C10100-O side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.