BeO Ceramic vs MgTiO3
Ceramic · grade comparison
BeO Ceramic and MgTiO3 are both ceramic grades. BeO Ceramic is the stronger of the two: tensile strength 140 MPa (20.3 ksi) against 70 MPa (10.2 ksi) for MgTiO3, about 100% more. BeO Ceramic is harder — 1,200 HV against 700 HV for MgTiO3 — which matters for wear surfaces and threads. BeO Ceramic is lighter (2.87 g/cm³ vs 3.8 g/cm³ for MgTiO3) and BeO Ceramic is stiffer (345 GPa vs 150 GPa).
BeO CeramicChoose it when strength drives the design, or when surface hardness matters.
BeO Ceramic vs MgTiO3: propertiesHow to read these bars
- One bar per material. A full bar is the highest value among all ceramic grades in the FabDigit library; each bar is drawn as a share of that.
- The better value (by the usual engineering direction) is in bold. Rows with no direction — density, thermal conductivity — have no bold.
- Values are typical room-temperature figures for the condition named on each card.
- Confirm against the certified mill or resin datasheet before design release.
How to read these bars
- One bar per material. A full bar is the highest value among all ceramic grades in the FabDigit library; each bar is drawn as a share of that.
- The better value (by the usual engineering direction) is in bold. Rows with no direction — density, thermal conductivity — have no bold.
- Values are typical room-temperature figures for the condition named on each card.
- Confirm against the certified mill or resin datasheet before design release.
Mechanical
Strength, stiffness, ductility and hardness at room temperature.
Elastic (Young's) Modulus
Shear Modulus
Bulk Modulus
Poisson's Ratio
Tensile Strength (Ultimate)
Compressive Strength
Flexural Strength
Fracture Toughness (K_IC)
Hardness, Vickers
Hardness, Knoop
Hardness, Mohs
Elongation at Break
Physical
Density and transition temperatures.
Density
Melting Point (Solidus)
Refractive Index
Same in both: Porosity 0.5%
Thermal
How each material carries heat and how hot it can run.
Thermal Conductivity
Specific Heat Capacity
Thermal Expansion (CTE, 20–100 °C)
Max Service Temperature (continuous)
Min Service Temperature
Electrical
Conductivity and insulation.
Electrical Resistivity
Dielectric Constant (1 MHz)
Dissipation Factor (1 MHz)
Volume Resistivity
Same in both: Dielectric Strength 12 kV/mm305 V/mil
Chemical & Environmental
Corrosion and environmental resistance (0–100 scores).
Same in both: Corrosion Resistance 85 / 100
Manufacturability
FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.
Polishability
Sintering / Firing Temperature
Same in both: Machinability 5 / 100
Sustainability
Primary-production footprint per kilogram.
Embodied Energy (primary production)
Embodied Carbon (primary production)
Embodied Water
Typical Recycled Content
Common Calculations
Ratios derived from the values above.
Specific Strength (UTS / density)
Specific Stiffness (E / density)
Thermal Diffusivity
Thermal Shock Resistance Index
Strength versus weight
Yield strength against density for every ceramic grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.
Manufacturing and finishing
| Capability | BeO Ceramic | MgTiO3 |
|---|---|---|
| Default condition | — | — |
| Relative cost | $$$$ High | $$$$ High |
| Min. machined wall | — | — |
| Best machined surface | — | — |
BeO Ceramic vs MgTiO3 — frequently asked
Is BeO Ceramic stronger than MgTiO3?
Yes. BeO Ceramic has a typical tensile strength of 140 MPa (20.3 ksi) against 70 MPa (10.2 ksi) for MgTiO3 — about 100% more.
Which is cheaper, BeO Ceramic or MgTiO3?
Both sit in the same relative cost tier ($$$$, high); the part price will be decided by machining time, tolerance and quantity rather than by the material.
When should I choose BeO Ceramic over MgTiO3?
Pick BeO Ceramic when strength drives the design, or when surface hardness matters.
Ready to make it?
Upload a CAD file and FabDigit prices the part in BeO Ceramic and MgTiO3 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.
Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.