FabDigitFabDigit

B4C vs WC-Co

Ceramic · grade comparison

B4C and WC-Co are both ceramic grades. WC-Co is the stronger of the two: tensile strength 1,500 MPa (218 ksi) against 300 MPa (43.5 ksi) for B4C, about 5.0 times as much. B4C is harder — 3,000 HV against 1,600 HV for WC-Co — which matters for wear surfaces and threads. B4C is lighter (2.51 g/cm³ vs 14.9 g/cm³ for WC-Co) and WC-Co is stiffer (630 GPa vs 450 GPa).

B4CChoose it when surface hardness matters, or when weight is the constraint.

WC-CoChoose it when strength drives the design.

B4C vs WC-Co: properties

B4CWC-Co

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

450 GPa65.3 Msi
630 GPa91.4 Msi

Shear Modulus

190 GPa27.6 Msi
250 GPa36.3 Msi

Bulk Modulus

240 GPa34.8 Msi
385 GPa55.8 Msi

Poisson's Ratio

0.17
0.22

Tensile Strength (Ultimate)

300 MPa43.5 ksi
1,500 MPa218 ksi

Compressive Strength

2,900 MPa421 ksi
5,800 MPa841 ksi

Flexural Strength

400 MPa58 ksi
2,100 MPa305 ksi

Shear Strength

260 MPa37.7 ksi
1,200 MPa174 ksi

Fracture Toughness (K_IC)

3 MPa·√m2.7 ksi·√in
9.5 MPa·√m8.6 ksi·√in

Hardness, Vickers

3,000 HV
1,600 HV

Hardness, Knoop

2,900 HK
1,800 HK

Hardness, Mohs

9.5
9

Elongation at Break

—
0%

Physical

Density and transition temperatures.

Density

2.51 g/cm³0.09 lb/in³
14.9 g/cm³0.54 lb/in³

Melting Point (Solidus)

2,450°C4,442 °F
1,320°C2,408 °F

Porosity

0.5%
0.04%

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

35 W/m·K20.2 BTU/hr·ft·°F
90 W/m·K52 BTU/hr·ft·°F

Specific Heat Capacity

960 J/kg·K0.23 BTU/lb·°F
220 J/kg·K0.05 BTU/lb·°F

Thermal Expansion (CTE, 20–100 °C)

4.5 µm/m·K2.5 µin/in·°F
5.2 µm/m·K2.9 µin/in·°F

Max Service Temperature (continuous)

800°C1,472 °F
550°C1,022 °F

Min Service Temperature

-269°C-452 °F
-200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Resistivity

0.05 Ω·m1,968,500 µΩ·in
2×10⁻⁷ Ω·m7.87 µΩ·in

Volume Resistivity

5 Ω·cm
2×10⁻⁵ Ω·cm

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

90 / 100
55 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Polishability

85 / 100
95 / 100

Sintering / Firing Temperature

2,150°C3,902 °F
1,420°C2,588 °F

Same in both: Machinability 3 / 100

Sustainability

Primary-production footprint per kilogram.

Embodied Energy (primary production)

260 MJ/kg111,780 BTU/lb
400 MJ/kg171,969 BTU/lb

Embodied Carbon (primary production)

22 kg CO₂/kg
28 kg CO₂/kg

Embodied Water

120 L/kg14.4 gal/lb
350 L/kg41.9 gal/lb

Typical Recycled Content

0%
30%

Common Calculations

Ratios derived from the values above.

Specific Strength (UTS / density)

120 kN·m/kg
101 kN·m/kg

Specific Stiffness (E / density)

179.3 MN·m/kg
42.3 MN·m/kg

Thermal Diffusivity

14.5 mm²/s
27.5 mm²/s

Thermal Shock Resistance Index

5
41

Strength versus weight

Yield strength against density for every ceramic grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,000234567Density (g/cm³)Yield strength (MPa) — log scale

Manufacturing and finishing

CapabilityB4CWC-Co
Default condition——
Relative cost$$$$ High$$$$ High
Min. machined wall——
Best machined surface——

B4C vs WC-Co — frequently asked

Is WC-Co stronger than B4C?

Yes. WC-Co has a typical tensile strength of 1,500 MPa (218 ksi) against 300 MPa (43.5 ksi) for B4C — about 5.0 times as much.

Which is cheaper, B4C or WC-Co?

Both sit in the same relative cost tier ($$$$, high); the part price will be decided by machining time, tolerance and quantity rather than by the material.

When should I choose B4C over WC-Co?

Pick B4C when surface hardness matters, or when weight is the constraint. Pick WC-Co when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in B4C and WC-Co side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.