EN AC-51500-O and EN AC-51500-T5 are two conditions of the same aluminum grade, EN AC-51500: O (annealed) versus T5 (cooled from hot working and artificially aged). The chemistry is identical, so every difference below comes from the condition. EN AC-51500-T5 is the stronger of the two: yield strength 230 MPa (33.4 ksi) against 130 MPa (18.9 ksi) for EN AC-51500-O, about 77% more; tensile strength follows at 305 MPa (44.2 ksi) vs 235 MPa (34.1 ksi). In exchange, EN AC-51500-O is the more ductile: elongation 20% versus 8% for EN AC-51500-T5, and EN AC-51500-T5 is harder (95 HB vs 65 HB). EN AC-51500-T5 runs hotter in service (120°C vs 100°C continuous). On the shop floor, EN AC-51500-T5 machines more easily (very good vs good).

EN AC-51500-OChoose it when the part is bent, formed or impact-loaded.

EN AC-51500-T5Choose it when strength drives the design, or when the part sees heat.

EN AC-51500-O vs EN AC-51500-T5: properties

EN AC-51500-OEN AC-51500-T5

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

235 MPa34.1 ksi
305 MPa44.2 ksi

Yield Strength (0.2% offset)

130 MPa18.9 ksi
230 MPa33.4 ksi

Elongation at Break

20%
8%

Shear Strength

150 MPa21.8 ksi
185 MPa26.8 ksi

Fatigue Strength (Endurance Limit)

90 MPa13.1 ksi
105 MPa15.2 ksi

Hardness, Brinell

65 HB
95 HB

Hardness, Vickers

70 HV
100 HV

Same in both: Elastic (Young's) Modulus 70 GPa10.2 Msi · Shear Modulus 26.5 GPa3.8 Msi · Bulk Modulus 69 GPa10 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.65 g/cm³0.1 lb/in³ · Melting Point (Solidus) 575°C1,067 °F · Liquidus Temperature 620°C1,148 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

108 W/m·K62.4 BTU/hr·ft·°F
104 W/m·K60.1 BTU/hr·ft·°F

Max Service Temperature (continuous)

100°C212 °F
120°C248 °F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 24 µm/m·K13.3 µin/in·°F · Latent Heat of Fusion 395 J/g170 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

30 % IACS
29 % IACS

Electrical Resistivity

5.75×10⁻⁸ Ω·m2.26 µΩ·in
5.95×10⁻⁸ Ω·m2.34 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

80 / 100
76 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.87 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

62 / 100
72 / 100

Machinability Rating (AISI 1212 = 100 %)

50%
62%

Weldability

62 / 100
58 / 100

Formability (cold)

45 / 100
15 / 100

Same in both: Castability 72 / 100 · Brazeability / Solderability 25 / 100 · Polishability 65 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,100 L/kg132 gal/lb · Typical Recycled Content 15%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scaleEN AC-51500

EN AC-51500-O vs EN AC-51500-T5 — frequently asked

Is EN AC-51500-T5 stronger than EN AC-51500-O?

Yes. EN AC-51500-T5 has a typical yield strength of 230 MPa (33.4 ksi) against 130 MPa (18.9 ksi) for EN AC-51500-O — about 77% more. Tensile strength is 305 MPa (44.2 ksi) vs 235 MPa (34.1 ksi).

Which condition does FabDigit quote by default, O or T5?

F is the default EN AC-51500 condition in the FabDigit quote flow (neither O nor T5). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, EN AC-51500-O or EN AC-51500-T5?

EN AC-51500-T5. Its machinability rates very good (72/100) against good (62/100) for EN AC-51500-O.

Ready to make it?

Upload a CAD file and FabDigit prices the part in EN AC-51500-O and EN AC-51500-T5 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.