FabDigitFabDigit

Aluminum EN AC-48100-F vs EN AC-48100-T6

Aluminum · EN AC-48100 temper comparison

EN AC-48100-F and EN AC-48100-T6 are two conditions of the same aluminum grade, EN AC-48100: F (as fabricated) versus T6 (solution heat treated and artificially aged). The chemistry is identical, so every difference below comes from the condition. EN AC-48100-T6 is the stronger of the two: yield strength 300 MPa (43.5 ksi) against 180 MPa (26.1 ksi) for EN AC-48100-F, about 67% more; tensile strength follows at 310 MPa (45 ksi) vs 190 MPa (27.6 ksi). EN AC-48100-T6 is harder — 145 HB against 105 HB for EN AC-48100-F — which matters for wear surfaces and threads. EN AC-48100-F runs hotter in service (250°C vs 175°C continuous). On the shop floor, EN AC-48100-F welds better (fair vs poor).

EN AC-48100-FChoose it when the part sees heat, or when it will be welded.

EN AC-48100-T6Choose it when strength drives the design, or when surface hardness matters.

EN AC-48100-F vs EN AC-48100-T6: properties

EN AC-48100-FEN AC-48100-T6

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

190 MPa27.6 ksi
310 MPa45 ksi

Yield Strength (0.2% offset)

180 MPa26.1 ksi
300 MPa43.5 ksi

Shear Strength

145 MPa21 ksi
220 MPa31.9 ksi

Fatigue Strength (Endurance Limit)

90 MPa13.1 ksi
105 MPa15.2 ksi

Fracture Toughness (K_IC)

14 MPa·√m12.7 ksi·√in
13 MPa·√m11.8 ksi·√in

Hardness, Brinell

105 HB
145 HB

Hardness, Vickers

110 HV
152 HV

Same in both: Elastic (Young's) Modulus 81 GPa11.7 Msi · Shear Modulus 30 GPa4.4 Msi · Bulk Modulus 76 GPa11 Msi · Poisson's Ratio 0.33 · Elongation at Break 0.8% · Charpy V-Notch Impact (RT) 2 J1.1 ft·lbf

Physical

Density and transition temperatures.

Same in both: Density 2.73 g/cm³0.1 lb/in³ · Melting Point (Solidus) 507°C945 °F · Liquidus Temperature 650°C1,202 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

250°C482 °F
175°C347 °F

Same in both: Thermal Conductivity 134 W/m·K77.4 BTU/hr·ft·°F · Specific Heat Capacity 963 J/kg·K0.23 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 18 µm/m·K10 µin/in·°F · Latent Heat of Fusion 490 J/g211 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

27 % IACS
25 % IACS

Electrical Resistivity

6.4×10⁻⁸ Ω·m2.52 µΩ·in
6.9×10⁻⁸ Ω·m2.72 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

48 / 100
38 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.78 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability Rating (AISI 1212 = 100 %)

25%
40%

Weldability

35 / 100
22 / 100

Formability (cold)

5 / 100
4 / 100

Same in both: Machinability 32 / 100 · Castability 70 / 100 · Brazeability / Solderability 25 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 55 MJ/kg23,646 BTU/lb · Embodied Carbon (primary production) 4 kg CO₂/kg · Embodied Water 900 L/kg108 gal/lb · Typical Recycled Content 70%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scaleEN AC-48100

EN AC-48100-F vs EN AC-48100-T6 — frequently asked

Is EN AC-48100-T6 stronger than EN AC-48100-F?

Yes. EN AC-48100-T6 has a typical yield strength of 300 MPa (43.5 ksi) against 180 MPa (26.1 ksi) for EN AC-48100-F — about 67% more. Tensile strength is 310 MPa (45 ksi) vs 190 MPa (27.6 ksi).

Which condition does FabDigit quote by default, F or T6?

F is the default EN AC-48100 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which welds better, EN AC-48100-F or EN AC-48100-T6?

EN AC-48100-F. Its weldability rates fair (35/100) against poor (22/100) for EN AC-48100-T6.

Ready to make it?

Upload a CAD file and FabDigit prices the part in EN AC-48100-F and EN AC-48100-T6 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.