FabDigitFabDigit

Aluminum EN AC-48100-T6 vs EN AC-48100-T7

Aluminum · EN AC-48100 temper comparison

EN AC-48100-T6 and EN AC-48100-T7 are two conditions of the same aluminum grade, EN AC-48100: T6 (solution heat treated and artificially aged) versus T7 (solution heat treated and overaged (stabilized)). The chemistry is identical, so every difference below comes from the condition. EN AC-48100-T6 is the stronger of the two: yield strength 300 MPa (43.5 ksi) against 250 MPa (36.3 ksi) for EN AC-48100-T7, about 20% more; tensile strength follows at 310 MPa (45 ksi) vs 260 MPa (37.7 ksi). In exchange, EN AC-48100-T7 is the more ductile: elongation 1% versus 0.8% for EN AC-48100-T6, and EN AC-48100-T6 is harder (145 HB vs 120 HB). EN AC-48100-T7 runs hotter in service (250°C vs 175°C continuous) and EN AC-48100-T7 conducts electricity better (30 % IACS vs 25 % IACS).

EN AC-48100-T6Choose it when strength drives the design.

EN AC-48100-T7Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

EN AC-48100-T6 vs EN AC-48100-T7: properties

EN AC-48100-T6EN AC-48100-T7

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

310 MPa45 ksi
260 MPa37.7 ksi

Yield Strength (0.2% offset)

300 MPa43.5 ksi
250 MPa36.3 ksi

Elongation at Break

0.8%
1%

Shear Strength

220 MPa31.9 ksi
190 MPa27.6 ksi

Fatigue Strength (Endurance Limit)

105 MPa15.2 ksi
100 MPa14.5 ksi

Fracture Toughness (K_IC)

13 MPa·√m11.8 ksi·√in
16 MPa·√m14.6 ksi·√in

Charpy V-Notch Impact (RT)

2 J1.1 ft·lbf
3 J1.8 ft·lbf

Hardness, Brinell

145 HB
120 HB

Hardness, Vickers

152 HV
126 HV

Same in both: Elastic (Young's) Modulus 81 GPa11.7 Msi · Shear Modulus 30 GPa4.4 Msi · Bulk Modulus 76 GPa11 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.73 g/cm³0.1 lb/in³ · Melting Point (Solidus) 507°C945 °F · Liquidus Temperature 650°C1,202 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

134 W/m·K77.4 BTU/hr·ft·°F
145 W/m·K83.8 BTU/hr·ft·°F

Max Service Temperature (continuous)

175°C347 °F
250°C482 °F

Same in both: Specific Heat Capacity 963 J/kg·K0.23 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 18 µm/m·K10 µin/in·°F · Latent Heat of Fusion 490 J/g211 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

25 % IACS
30 % IACS

Electrical Resistivity

6.9×10⁻⁸ Ω·m2.72 µΩ·in
5.75×10⁻⁸ Ω·m2.26 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

38 / 100
44 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.78 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

32 / 100
36 / 100

Machinability Rating (AISI 1212 = 100 %)

40%
48%

Weldability

22 / 100
28 / 100

Formability (cold)

4 / 100
6 / 100

Same in both: Castability 70 / 100 · Brazeability / Solderability 25 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 55 MJ/kg23,646 BTU/lb · Embodied Carbon (primary production) 4 kg CO₂/kg · Embodied Water 900 L/kg108 gal/lb · Typical Recycled Content 70%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scaleEN AC-48100

EN AC-48100-T6 vs EN AC-48100-T7 — frequently asked

Is EN AC-48100-T6 stronger than EN AC-48100-T7?

Yes. EN AC-48100-T6 has a typical yield strength of 300 MPa (43.5 ksi) against 250 MPa (36.3 ksi) for EN AC-48100-T7 — about 20% more. Tensile strength is 310 MPa (45 ksi) vs 260 MPa (37.7 ksi).

Which condition does FabDigit quote by default, T6 or T7?

F is the default EN AC-48100 condition in the FabDigit quote flow (neither T6 nor T7). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which welds better, EN AC-48100-T6 or EN AC-48100-T7?

EN AC-48100-T7. Its weldability rates poor (28/100) against poor (22/100) for EN AC-48100-T6.

Ready to make it?

Upload a CAD file and FabDigit prices the part in EN AC-48100-T6 and EN AC-48100-T7 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.