FabDigitFabDigit

Aluminum EN AC-48100-F vs EN AC-48100-T5

Aluminum · EN AC-48100 temper comparison

EN AC-48100-F and EN AC-48100-T5 are two conditions of the same aluminum grade, EN AC-48100: F (as fabricated) versus T5 (cooled from hot working and artificially aged). The chemistry is identical, so every difference below comes from the condition. EN AC-48100-T5 is the stronger of the two: yield strength 195 MPa (28.3 ksi) against 180 MPa (26.1 ksi) for EN AC-48100-F, about 8% more; tensile strength follows at 210 MPa (30.5 ksi) vs 190 MPa (27.6 ksi). In exchange, EN AC-48100-F is the more ductile: elongation 0.8% versus 0.7% for EN AC-48100-T5, and EN AC-48100-T5 is harder (115 HB vs 105 HB). EN AC-48100-F runs hotter in service (250°C vs 200°C continuous).

EN AC-48100-FChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

EN AC-48100-T5Choose it when strength drives the design.

EN AC-48100-F vs EN AC-48100-T5: properties

EN AC-48100-FEN AC-48100-T5

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

190 MPa27.6 ksi
210 MPa30.5 ksi

Yield Strength (0.2% offset)

180 MPa26.1 ksi
195 MPa28.3 ksi

Elongation at Break

0.8%
0.7%

Shear Strength

145 MPa21 ksi
155 MPa22.5 ksi

Fatigue Strength (Endurance Limit)

90 MPa13.1 ksi
95 MPa13.8 ksi

Fracture Toughness (K_IC)

14 MPa·√m12.7 ksi·√in
13 MPa·√m11.8 ksi·√in

Charpy V-Notch Impact (RT)

2 J1.1 ft·lbf
1 J0.89 ft·lbf

Hardness, Brinell

105 HB
115 HB

Hardness, Vickers

110 HV
121 HV

Same in both: Elastic (Young's) Modulus 81 GPa11.7 Msi · Shear Modulus 30 GPa4.4 Msi · Bulk Modulus 76 GPa11 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.73 g/cm³0.1 lb/in³ · Melting Point (Solidus) 507°C945 °F · Liquidus Temperature 650°C1,202 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

250°C482 °F
200°C392 °F

Same in both: Thermal Conductivity 134 W/m·K77.4 BTU/hr·ft·°F · Specific Heat Capacity 963 J/kg·K0.23 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 18 µm/m·K10 µin/in·°F · Latent Heat of Fusion 490 J/g211 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 27 % IACS · Electrical Resistivity 6.4×10⁻⁸ Ω·m2.52 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.78 V · Corrosion Resistance 48 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

32 / 100
30 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 25% · Weldability 35 / 100 · Formability (cold) 5 / 100 · Castability 70 / 100 · Brazeability / Solderability 25 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Embodied Energy (primary production)

55 MJ/kg23,646 BTU/lb
57 MJ/kg24,506 BTU/lb

Embodied Carbon (primary production)

4 kg CO₂/kg
4.1 kg CO₂/kg

Same in both: Embodied Water 900 L/kg108 gal/lb · Typical Recycled Content 70%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scaleEN AC-48100

EN AC-48100-F vs EN AC-48100-T5 — frequently asked

Is EN AC-48100-T5 stronger than EN AC-48100-F?

Yes. EN AC-48100-T5 has a typical yield strength of 195 MPa (28.3 ksi) against 180 MPa (26.1 ksi) for EN AC-48100-F — about 8% more. Tensile strength is 210 MPa (30.5 ksi) vs 190 MPa (27.6 ksi).

Which condition does FabDigit quote by default, F or T5?

F is the default EN AC-48100 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose EN AC-48100-F over EN AC-48100-T5?

Pick EN AC-48100-F when the part is bent, formed or impact-loaded, or when the part sees heat. Pick EN AC-48100-T5 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in EN AC-48100-F and EN AC-48100-T5 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.