EN AC-45500-T6 and EN AC-45500-T7 are two conditions of the same aluminum grade, EN AC-45500: T6 (solution heat treated and artificially aged) versus T7 (solution heat treated and overaged (stabilized)). The chemistry is identical, so every difference below comes from the condition. EN AC-45500-T6 is the stronger of the two: yield strength 280 MPa (40.6 ksi) against 210 MPa (30.5 ksi) for EN AC-45500-T7, about 33% more; tensile strength follows at 320 MPa (46.4 ksi) vs 260 MPa (37.7 ksi). In exchange, EN AC-45500-T7 is the more ductile: elongation 5% versus 4% for EN AC-45500-T6, and EN AC-45500-T6 is harder (100 HB vs 85 HB). EN AC-45500-T7 runs hotter in service (200°C vs 150°C continuous).

EN AC-45500-T6Choose it when strength drives the design.

EN AC-45500-T7Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

EN AC-45500-T6 vs EN AC-45500-T7: properties

EN AC-45500-T6EN AC-45500-T7

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

75 GPa10.9 Msi
74 GPa10.7 Msi

Tensile Strength (Ultimate)

320 MPa46.4 ksi
260 MPa37.7 ksi

Yield Strength (0.2% offset)

280 MPa40.6 ksi
210 MPa30.5 ksi

Elongation at Break

4%
5%

Compressive Strength

285 MPa41.3 ksi
215 MPa31.2 ksi

Shear Strength

210 MPa30.5 ksi
175 MPa25.4 ksi

Fatigue Strength (Endurance Limit)

95 MPa13.8 ksi
85 MPa12.3 ksi

Fracture Toughness (K_IC)

22 MPa·√m20 ksi·√in
26 MPa·√m23.7 ksi·√in

Charpy V-Notch Impact (RT)

5 J3.7 ft·lbf
8 J5.9 ft·lbf

Hardness, Brinell

100 HB
85 HB

Hardness, Vickers

105 HV
90 HV

Same in both: Shear Modulus 27 GPa3.9 Msi · Bulk Modulus 75 GPa10.9 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.68 g/cm³0.1 lb/in³ · Melting Point (Solidus) 555°C1,031 °F · Liquidus Temperature 615°C1,139 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

150 W/m·K86.7 BTU/hr·ft·°F
160 W/m·K92.4 BTU/hr·ft·°F

Max Service Temperature (continuous)

150°C302 °F
200°C392 °F

Same in both: Specific Heat Capacity 963 J/kg·K0.23 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 21.5 µm/m·K11.9 µin/in·°F · Latent Heat of Fusion 400 J/g172 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

39 % IACS
41 % IACS

Electrical Resistivity

4.4×10⁻⁸ Ω·m1.73 µΩ·in
4.2×10⁻⁸ Ω·m1.65 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

55 / 100
58 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.83 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

68 / 100
64 / 100

Machinability Rating (AISI 1212 = 100 %)

80%
75%

Same in both: Weldability 55 / 100 · Castability 88 / 100 · Brazeability / Solderability 25 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scaleEN AC-45500

EN AC-45500-T6 vs EN AC-45500-T7 — frequently asked

Is EN AC-45500-T6 stronger than EN AC-45500-T7?

Yes. EN AC-45500-T6 has a typical yield strength of 280 MPa (40.6 ksi) against 210 MPa (30.5 ksi) for EN AC-45500-T7 — about 33% more. Tensile strength is 320 MPa (46.4 ksi) vs 260 MPa (37.7 ksi).

Which condition does FabDigit quote by default, T6 or T7?

T6 is the default EN AC-45500 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose EN AC-45500-T6 over EN AC-45500-T7?

Pick EN AC-45500-T6 when strength drives the design. Pick EN AC-45500-T7 when the part is bent, formed or impact-loaded, or when the part sees heat.

Ready to make it?

Upload a CAD file and FabDigit prices the part in EN AC-45500-T6 and EN AC-45500-T7 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.