Aluminum EN AC-45500-F vs EN AC-45500-T7
Aluminum · EN AC-45500 temper comparison
EN AC-45500-F and EN AC-45500-T7 are two conditions of the same aluminum grade, EN AC-45500: F (as fabricated) versus T7 (solution heat treated and overaged (stabilized)). The chemistry is identical, so every difference below comes from the condition. EN AC-45500-T7 is the stronger of the two: yield strength 210 MPa (30.5 ksi) against 100 MPa (14.5 ksi) for EN AC-45500-F, about 110% more; tensile strength follows at 260 MPa (37.7 ksi) vs 180 MPa (26.1 ksi). EN AC-45500-T7 is the more ductile: elongation 5% versus 3% for EN AC-45500-F, and EN AC-45500-T7 is harder (85 HB vs 60 HB). EN AC-45500-T7 runs hotter in service (200°C vs 150°C continuous).
EN AC-45500-T7Choose it when strength drives the design, or when the part is bent, formed or impact-loaded.
EN AC-45500-F vs EN AC-45500-T7: propertiesHow to read these bars
- One bar per material. A full bar is the highest value among all aluminum grades in the FabDigit library; each bar is drawn as a share of that.
- The better value (by the usual engineering direction) is in bold. Rows with no direction — density, thermal conductivity — have no bold.
- Values are typical room-temperature figures for the condition named on each card.
- Confirm against the certified mill or resin datasheet before design release.
How to read these bars
- One bar per material. A full bar is the highest value among all aluminum grades in the FabDigit library; each bar is drawn as a share of that.
- The better value (by the usual engineering direction) is in bold. Rows with no direction — density, thermal conductivity — have no bold.
- Values are typical room-temperature figures for the condition named on each card.
- Confirm against the certified mill or resin datasheet before design release.
Mechanical
Strength, stiffness, ductility and hardness at room temperature.
Tensile Strength (Ultimate)
Yield Strength (0.2% offset)
Elongation at Break
Compressive Strength
Shear Strength
Fatigue Strength (Endurance Limit)
Charpy V-Notch Impact (RT)
Hardness, Brinell
Hardness, Vickers
Same in both: Elastic (Young's) Modulus 74 GPa10.7 Msi · Shear Modulus 27 GPa3.9 Msi · Bulk Modulus 75 GPa10.9 Msi · Poisson's Ratio 0.33 · Fracture Toughness (K_IC) 26 MPa·√m23.7 ksi·√in
Physical
Density and transition temperatures.
Same in both: Density 2.68 g/cm³0.1 lb/in³ · Melting Point (Solidus) 555°C1,031 °F · Liquidus Temperature 615°C1,139 °F
Thermal
How each material carries heat and how hot it can run.
Thermal Conductivity
Max Service Temperature (continuous)
Same in both: Specific Heat Capacity 963 J/kg·K0.23 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 21.5 µm/m·K11.9 µin/in·°F · Latent Heat of Fusion 400 J/g172 BTU/lb · Min Service Temperature -196°C-321 °F
Electrical
Conductivity and insulation.
Electrical Conductivity
Electrical Resistivity
Chemical & Environmental
Corrosion and environmental resistance (0–100 scores).
Same in both: Galvanic Potential (seawater, vs SCE) -0.83 V · Corrosion Resistance 58 / 100
Manufacturability
FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.
Machinability
Machinability Rating (AISI 1212 = 100 %)
Weldability
Same in both: Castability 88 / 100 · Brazeability / Solderability 25 / 100 · Polishability 45 / 100
Sustainability
Primary-production footprint per kilogram.
Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 25%
Strength versus weight
Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.
EN AC-45500-F vs EN AC-45500-T7 — frequently asked
Is EN AC-45500-T7 stronger than EN AC-45500-F?
Yes. EN AC-45500-T7 has a typical yield strength of 210 MPa (30.5 ksi) against 100 MPa (14.5 ksi) for EN AC-45500-F — about 110% more. Tensile strength is 260 MPa (37.7 ksi) vs 180 MPa (26.1 ksi).
Which condition does FabDigit quote by default, F or T7?
T6 is the default EN AC-45500 condition in the FabDigit quote flow (neither F nor T7). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.
Which is easier to machine, EN AC-45500-F or EN AC-45500-T7?
EN AC-45500-T7, by a small margin. Both rate good for machinability — 64/100 against 55/100 for EN AC-45500-F; for welding the order is EN AC-45500-T7 first (good, 55/100) then EN AC-45500-F (fair, 50/100).
Ready to make it?
Upload a CAD file and FabDigit prices the part in EN AC-45500-F and EN AC-45500-T7 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.
Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.
