EN AC-45500-T4 and EN AC-45500-T6 are two conditions of the same aluminum grade, EN AC-45500: T4 (solution heat treated and naturally aged) versus T6 (solution heat treated and artificially aged). The chemistry is identical, so every difference below comes from the condition. EN AC-45500-T6 is the stronger of the two: yield strength 280 MPa (40.6 ksi) against 130 MPa (18.9 ksi) for EN AC-45500-T4, about 115% more; tensile strength follows at 320 MPa (46.4 ksi) vs 230 MPa (33.4 ksi). In exchange, EN AC-45500-T4 is the more ductile: elongation 9% versus 4% for EN AC-45500-T6, and EN AC-45500-T6 is harder (100 HB vs 70 HB). EN AC-45500-T6 runs hotter in service (150°C vs 120°C continuous).

EN AC-45500-T4Choose it when the part is bent, formed or impact-loaded.

EN AC-45500-T6Choose it when strength drives the design, or when the part sees heat.

EN AC-45500-T4 vs EN AC-45500-T6: properties

EN AC-45500-T4EN AC-45500-T6

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

74 GPa10.7 Msi
75 GPa10.9 Msi

Tensile Strength (Ultimate)

230 MPa33.4 ksi
320 MPa46.4 ksi

Yield Strength (0.2% offset)

130 MPa18.9 ksi
280 MPa40.6 ksi

Elongation at Break

9%
4%

Compressive Strength

135 MPa19.6 ksi
285 MPa41.3 ksi

Shear Strength

155 MPa22.5 ksi
210 MPa30.5 ksi

Fatigue Strength (Endurance Limit)

75 MPa10.9 ksi
95 MPa13.8 ksi

Fracture Toughness (K_IC)

30 MPa·√m27.3 ksi·√in
22 MPa·√m20 ksi·√in

Charpy V-Notch Impact (RT)

12 J8.9 ft·lbf
5 J3.7 ft·lbf

Hardness, Brinell

70 HB
100 HB

Hardness, Vickers

75 HV
105 HV

Same in both: Shear Modulus 27 GPa3.9 Msi · Bulk Modulus 75 GPa10.9 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.68 g/cm³0.1 lb/in³ · Melting Point (Solidus) 555°C1,031 °F · Liquidus Temperature 615°C1,139 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

142 W/m·K82 BTU/hr·ft·°F
150 W/m·K86.7 BTU/hr·ft·°F

Max Service Temperature (continuous)

120°C248 °F
150°C302 °F

Same in both: Specific Heat Capacity 963 J/kg·K0.23 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 21.5 µm/m·K11.9 µin/in·°F · Latent Heat of Fusion 400 J/g172 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

36 % IACS
39 % IACS

Electrical Resistivity

4.79×10⁻⁸ Ω·m1.89 µΩ·in
4.4×10⁻⁸ Ω·m1.73 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.83 V · Corrosion Resistance 55 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

60 / 100
68 / 100

Machinability Rating (AISI 1212 = 100 %)

70%
80%

Same in both: Weldability 55 / 100 · Castability 88 / 100 · Brazeability / Solderability 25 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scaleEN AC-45500

EN AC-45500-T4 vs EN AC-45500-T6 — frequently asked

Is EN AC-45500-T6 stronger than EN AC-45500-T4?

Yes. EN AC-45500-T6 has a typical yield strength of 280 MPa (40.6 ksi) against 130 MPa (18.9 ksi) for EN AC-45500-T4 — about 115% more. Tensile strength is 320 MPa (46.4 ksi) vs 230 MPa (33.4 ksi).

Which condition does FabDigit quote by default, T4 or T6?

T6 is the default EN AC-45500 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, EN AC-45500-T4 or EN AC-45500-T6?

EN AC-45500-T6, by a small margin. Both rate good for machinability — 68/100 against 60/100 for EN AC-45500-T4.

Ready to make it?