FabDigitFabDigit

Aluminum EN AC-45300-F vs EN AC-45300-T6

Aluminum · EN AC-45300 temper comparison

EN AC-45300-F and EN AC-45300-T6 are two conditions of the same aluminum grade, EN AC-45300: F (as fabricated) versus T6 (solution heat treated and artificially aged). The chemistry is identical, so every difference below comes from the condition. EN AC-45300-T6 is the stronger of the two: yield strength 200 MPa (29 ksi) against 90 MPa (13.1 ksi) for EN AC-45300-F, about 122% more; tensile strength follows at 255 MPa (37 ksi) vs 160 MPa (23.2 ksi). In exchange, EN AC-45300-F is the more ductile: elongation 2% versus 1.5% for EN AC-45300-T6, and EN AC-45300-T6 is harder (95 HB vs 60 HB). EN AC-45300-T6 runs hotter in service (175°C vs 150°C continuous).

EN AC-45300-FChoose it when the part is bent, formed or impact-loaded.

EN AC-45300-T6Choose it when strength drives the design, or when the part sees heat.

EN AC-45300-F vs EN AC-45300-T6: properties

EN AC-45300-FEN AC-45300-T6

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

160 MPa23.2 ksi
255 MPa37 ksi

Yield Strength (0.2% offset)

90 MPa13.1 ksi
200 MPa29 ksi

Elongation at Break

2%
1.5%

Compressive Strength

95 MPa13.8 ksi
210 MPa30.5 ksi

Shear Strength

125 MPa18.1 ksi
195 MPa28.3 ksi

Fatigue Strength (Endurance Limit)

55 MPa8 ksi
75 MPa10.9 ksi

Fracture Toughness (K_IC)

15 MPa·√m13.7 ksi·√in
18 MPa·√m16.4 ksi·√in

Hardness, Brinell

60 HB
95 HB

Same in both: Elastic (Young's) Modulus 71 GPa10.3 Msi · Shear Modulus 26.5 GPa3.8 Msi · Bulk Modulus 70 GPa10.2 Msi · Poisson's Ratio 0.33 · Charpy V-Notch Impact (RT) 3 J2.2 ft·lbf

Physical

Density and transition temperatures.

Same in both: Density 2.71 g/cm³0.1 lb/in³ · Melting Point (Solidus) 550°C1,022 °F · Liquidus Temperature 620°C1,148 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

160 W/m·K92.4 BTU/hr·ft·°F
150 W/m·K86.7 BTU/hr·ft·°F

Max Service Temperature (continuous)

150°C302 °F
175°C347 °F

Same in both: Specific Heat Capacity 963 J/kg·K0.23 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 22 µm/m·K12.2 µin/in·°F · Latent Heat of Fusion 389 J/g167 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

42 % IACS
39 % IACS

Electrical Resistivity

4.1×10⁻⁸ Ω·m1.61 µΩ·in
4.4×10⁻⁸ Ω·m1.73 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

45 / 100
52 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.78 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

62 / 100
70 / 100

Machinability Rating (AISI 1212 = 100 %)

120%
70%

Weldability

50 / 100
55 / 100

Same in both: Formability (cold) 8 / 100 · Castability 80 / 100 · Brazeability / Solderability 30 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 195 MJ/kg83,835 BTU/lb · Embodied Carbon (primary production) 12 kg CO₂/kg · Embodied Water 1,150 L/kg138 gal/lb · Typical Recycled Content 45%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scaleEN AC-45300

EN AC-45300-F vs EN AC-45300-T6 — frequently asked

Is EN AC-45300-T6 stronger than EN AC-45300-F?

Yes. EN AC-45300-T6 has a typical yield strength of 200 MPa (29 ksi) against 90 MPa (13.1 ksi) for EN AC-45300-F — about 122% more. Tensile strength is 255 MPa (37 ksi) vs 160 MPa (23.2 ksi).

Which condition does FabDigit quote by default, F or T6?

T6 is the default EN AC-45300 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, EN AC-45300-F or EN AC-45300-T6?

EN AC-45300-T6. Its machinability rates very good (70/100) against good (62/100) for EN AC-45300-F; for welding the order is EN AC-45300-T6 first (good, 55/100) then EN AC-45300-F (fair, 50/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in EN AC-45300-F and EN AC-45300-T6 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.