FabDigitFabDigit

Aluminum EN AC-45300-F vs EN AC-45300-T7

Aluminum · EN AC-45300 temper comparison

EN AC-45300-F and EN AC-45300-T7 are two conditions of the same aluminum grade, EN AC-45300: F (as fabricated) versus T7 (solution heat treated and overaged (stabilized)). The chemistry is identical, so every difference below comes from the condition. EN AC-45300-T7 is the stronger of the two: yield strength 165 MPa (23.9 ksi) against 90 MPa (13.1 ksi) for EN AC-45300-F, about 83% more; tensile strength follows at 210 MPa (30.5 ksi) vs 160 MPa (23.2 ksi). EN AC-45300-T7 is the more ductile: elongation 2.5% versus 2% for EN AC-45300-F, and EN AC-45300-T7 is harder (80 HB vs 60 HB). EN AC-45300-T7 runs hotter in service (175°C vs 150°C continuous).

EN AC-45300-T7Choose it when strength drives the design, or when the part is bent, formed or impact-loaded.

EN AC-45300-F vs EN AC-45300-T7: properties

EN AC-45300-FEN AC-45300-T7

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

160 MPa23.2 ksi
210 MPa30.5 ksi

Yield Strength (0.2% offset)

90 MPa13.1 ksi
165 MPa23.9 ksi

Elongation at Break

2%
2.5%

Compressive Strength

95 MPa13.8 ksi
170 MPa24.7 ksi

Shear Strength

125 MPa18.1 ksi
165 MPa23.9 ksi

Fatigue Strength (Endurance Limit)

55 MPa8 ksi
65 MPa9.4 ksi

Fracture Toughness (K_IC)

15 MPa·√m13.7 ksi·√in
19 MPa·√m17.3 ksi·√in

Charpy V-Notch Impact (RT)

3 J2.2 ft·lbf
5 J3.7 ft·lbf

Hardness, Brinell

60 HB
80 HB

Same in both: Elastic (Young's) Modulus 71 GPa10.3 Msi · Shear Modulus 26.5 GPa3.8 Msi · Bulk Modulus 70 GPa10.2 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.71 g/cm³0.1 lb/in³ · Melting Point (Solidus) 550°C1,022 °F · Liquidus Temperature 620°C1,148 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

160 W/m·K92.4 BTU/hr·ft·°F
158 W/m·K91.3 BTU/hr·ft·°F

Max Service Temperature (continuous)

150°C302 °F
175°C347 °F

Same in both: Specific Heat Capacity 963 J/kg·K0.23 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 22 µm/m·K12.2 µin/in·°F · Latent Heat of Fusion 389 J/g167 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 42 % IACS · Electrical Resistivity 4.1×10⁻⁸ Ω·m1.61 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

45 / 100
50 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.78 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

62 / 100
68 / 100

Machinability Rating (AISI 1212 = 100 %)

120%
140%

Weldability

50 / 100
45 / 100

Same in both: Formability (cold) 8 / 100 · Castability 80 / 100 · Brazeability / Solderability 30 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 195 MJ/kg83,835 BTU/lb · Embodied Carbon (primary production) 12 kg CO₂/kg · Embodied Water 1,150 L/kg138 gal/lb · Typical Recycled Content 45%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scaleEN AC-45300

EN AC-45300-F vs EN AC-45300-T7 — frequently asked

Is EN AC-45300-T7 stronger than EN AC-45300-F?

Yes. EN AC-45300-T7 has a typical yield strength of 165 MPa (23.9 ksi) against 90 MPa (13.1 ksi) for EN AC-45300-F — about 83% more. Tensile strength is 210 MPa (30.5 ksi) vs 160 MPa (23.2 ksi).

Which condition does FabDigit quote by default, F or T7?

T6 is the default EN AC-45300 condition in the FabDigit quote flow (neither F nor T7). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, EN AC-45300-F or EN AC-45300-T7?

EN AC-45300-T7, by a small margin. Both rate good for machinability — 68/100 against 62/100 for EN AC-45300-F; for welding the order is EN AC-45300-F first (fair, 50/100) then EN AC-45300-T7 (fair, 45/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in EN AC-45300-F and EN AC-45300-T7 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.