FabDigitFabDigit

Aluminum EN AC-42200-F vs EN AC-42200-T6

Aluminum · EN AC-42200 temper comparison

EN AC-42200-F and EN AC-42200-T6 are two conditions of the same aluminum grade, EN AC-42200: F (as fabricated) versus T6 (solution heat treated and artificially aged). The chemistry is identical, so every difference below comes from the condition. EN AC-42200-T6 is the stronger of the two: yield strength 250 MPa (36.3 ksi) against 90 MPa (13.1 ksi) for EN AC-42200-F, about 178% more; tensile strength follows at 320 MPa (46.4 ksi) vs 180 MPa (26.1 ksi). In exchange, EN AC-42200-F is the more ductile: elongation 5% versus 4% for EN AC-42200-T6, and EN AC-42200-T6 is harder (105 HB vs 55 HB). EN AC-42200-F runs hotter in service (175°C vs 150°C continuous).

EN AC-42200-FChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

EN AC-42200-T6Choose it when strength drives the design.

EN AC-42200-F vs EN AC-42200-T6: properties

EN AC-42200-FEN AC-42200-T6

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

180 MPa26.1 ksi
320 MPa46.4 ksi

Yield Strength (0.2% offset)

90 MPa13.1 ksi
250 MPa36.3 ksi

Elongation at Break

5%
4%

Fatigue Strength (Endurance Limit)

60 MPa8.7 ksi
90 MPa13.1 ksi

Hardness, Brinell

55 HB
105 HB

Same in both: Elastic (Young's) Modulus 72 GPa10.4 Msi · Shear Modulus 27 GPa3.9 Msi · Bulk Modulus 70 GPa10.2 Msi · Poisson's Ratio 0.33 · Compressive Strength 255 MPa37 ksi · Shear Strength 210 MPa30.5 ksi · Fracture Toughness (K_IC) 25 MPa·√m22.8 ksi·√in · Charpy V-Notch Impact (RT) 6 J4.4 ft·lbf · Hardness, Vickers 110 HV

Physical

Density and transition temperatures.

Same in both: Density 2.67 g/cm³0.1 lb/in³ · Melting Point (Solidus) 557°C1,035 °F · Liquidus Temperature 613°C1,135 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

158 W/m·K91.3 BTU/hr·ft·°F
151 W/m·K87.2 BTU/hr·ft·°F

Max Service Temperature (continuous)

175°C347 °F
150°C302 °F

Same in both: Specific Heat Capacity 963 J/kg·K0.23 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 21.5 µm/m·K11.9 µin/in·°F · Latent Heat of Fusion 425 J/g183 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

41 % IACS
39 % IACS

Same in both: Electrical Resistivity 4.4×10⁻⁸ Ω·m1.73 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.83 V · Corrosion Resistance 58 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

60 / 100
55 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 60% · Weldability 70 / 100 · Formability (cold) 15 / 100 · Castability 90 / 100 · Brazeability / Solderability 30 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 155 MJ/kg66,638 BTU/lb · Embodied Carbon (primary production) 9.5 kg CO₂/kg · Embodied Water 1,100 L/kg132 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scaleEN AC-42200

EN AC-42200-F vs EN AC-42200-T6 — frequently asked

Is EN AC-42200-T6 stronger than EN AC-42200-F?

Yes. EN AC-42200-T6 has a typical yield strength of 250 MPa (36.3 ksi) against 90 MPa (13.1 ksi) for EN AC-42200-F — about 178% more. Tensile strength is 320 MPa (46.4 ksi) vs 180 MPa (26.1 ksi).

Which condition does FabDigit quote by default, F or T6?

T6 is the default EN AC-42200 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, EN AC-42200-F or EN AC-42200-T6?

EN AC-42200-F, by a small margin. Both rate good for machinability — 60/100 against 55/100 for EN AC-42200-T6.

Ready to make it?

Upload a CAD file and FabDigit prices the part in EN AC-42200-F and EN AC-42200-T6 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.