FabDigitFabDigit

Aluminum EN AC-42200-F vs EN AC-42200-T61

Aluminum · EN AC-42200 temper comparison

EN AC-42200-F and EN AC-42200-T61 are two conditions of the same aluminum grade, EN AC-42200: F (as fabricated) versus T61 (T6 variant, underaged). The chemistry is identical, so every difference below comes from the condition. EN AC-42200-T61 is the stronger of the two: yield strength 285 MPa (41.3 ksi) against 90 MPa (13.1 ksi) for EN AC-42200-F, about 3.2 times as much; tensile strength follows at 345 MPa (50 ksi) vs 180 MPa (26.1 ksi). EN AC-42200-T61 is harder — 105 HB against 55 HB for EN AC-42200-F — which matters for wear surfaces and threads. EN AC-42200-F runs hotter in service (175°C vs 150°C continuous). On the shop floor, EN AC-42200-T61 machines more easily (very good vs good).

EN AC-42200-FChoose it when the part sees heat.

EN AC-42200-T61Choose it when strength drives the design, or when surface hardness matters.

EN AC-42200-F vs EN AC-42200-T61: properties

EN AC-42200-FEN AC-42200-T61

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

180 MPa26.1 ksi
345 MPa50 ksi

Yield Strength (0.2% offset)

90 MPa13.1 ksi
285 MPa41.3 ksi

Fatigue Strength (Endurance Limit)

60 MPa8.7 ksi
95 MPa13.8 ksi

Hardness, Brinell

55 HB
105 HB

Same in both: Elastic (Young's) Modulus 72 GPa10.4 Msi · Shear Modulus 27 GPa3.9 Msi · Bulk Modulus 70 GPa10.2 Msi · Poisson's Ratio 0.33 · Elongation at Break 5% · Compressive Strength 255 MPa37 ksi · Shear Strength 210 MPa30.5 ksi · Fracture Toughness (K_IC) 25 MPa·√m22.8 ksi·√in · Charpy V-Notch Impact (RT) 6 J4.4 ft·lbf · Hardness, Vickers 110 HV

Physical

Density and transition temperatures.

Same in both: Density 2.67 g/cm³0.1 lb/in³ · Melting Point (Solidus) 557°C1,035 °F · Liquidus Temperature 613°C1,135 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

158 W/m·K91.3 BTU/hr·ft·°F
150 W/m·K86.7 BTU/hr·ft·°F

Max Service Temperature (continuous)

175°C347 °F
150°C302 °F

Same in both: Specific Heat Capacity 963 J/kg·K0.23 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 21.5 µm/m·K11.9 µin/in·°F · Latent Heat of Fusion 425 J/g183 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

41 % IACS
39 % IACS

Same in both: Electrical Resistivity 4.4×10⁻⁸ Ω·m1.73 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.83 V · Corrosion Resistance 58 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

60 / 100
70 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 60% · Weldability 70 / 100 · Formability (cold) 15 / 100 · Castability 90 / 100 · Brazeability / Solderability 30 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 155 MJ/kg66,638 BTU/lb · Embodied Carbon (primary production) 9.5 kg CO₂/kg · Embodied Water 1,100 L/kg132 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scaleEN AC-42200

EN AC-42200-F vs EN AC-42200-T61 — frequently asked

Is EN AC-42200-T61 stronger than EN AC-42200-F?

Yes. EN AC-42200-T61 has a typical yield strength of 285 MPa (41.3 ksi) against 90 MPa (13.1 ksi) for EN AC-42200-F — about 3.2 times as much. Tensile strength is 345 MPa (50 ksi) vs 180 MPa (26.1 ksi).

Which condition does FabDigit quote by default, F or T61?

T6 is the default EN AC-42200 condition in the FabDigit quote flow (neither F nor T61). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, EN AC-42200-F or EN AC-42200-T61?

EN AC-42200-T61. Its machinability rates very good (70/100) against good (60/100) for EN AC-42200-F.

Ready to make it?

Upload a CAD file and FabDigit prices the part in EN AC-42200-F and EN AC-42200-T61 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.