EN AC-42200-T5 and EN AC-42200-T6 are two conditions of the same aluminum grade, EN AC-42200: T5 (cooled from hot working and artificially aged) versus T6 (solution heat treated and artificially aged). The chemistry is identical, so every difference below comes from the condition. EN AC-42200-T6 is the stronger of the two: yield strength 250 MPa (36.3 ksi) against 150 MPa (21.8 ksi) for EN AC-42200-T5, about 67% more; tensile strength follows at 320 MPa (46.4 ksi) vs 210 MPa (30.5 ksi). EN AC-42200-T6 is harder — 105 HB against 70 HB for EN AC-42200-T5 — which matters for wear surfaces and threads.

EN AC-42200-T6Choose it when strength drives the design, or when surface hardness matters.

EN AC-42200-T5 vs EN AC-42200-T6: properties

EN AC-42200-T5EN AC-42200-T6

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

210 MPa30.5 ksi
320 MPa46.4 ksi

Yield Strength (0.2% offset)

150 MPa21.8 ksi
250 MPa36.3 ksi

Compressive Strength

155 MPa22.5 ksi
255 MPa37 ksi

Shear Strength

140 MPa20.3 ksi
210 MPa30.5 ksi

Fatigue Strength (Endurance Limit)

70 MPa10.2 ksi
90 MPa13.1 ksi

Fracture Toughness (K_IC)

30 MPa·√m27.3 ksi·√in
25 MPa·√m22.8 ksi·√in

Charpy V-Notch Impact (RT)

5 J3.7 ft·lbf
6 J4.4 ft·lbf

Hardness, Brinell

70 HB
105 HB

Hardness, Vickers

75 HV
110 HV

Same in both: Elastic (Young's) Modulus 72 GPa10.4 Msi · Shear Modulus 27 GPa3.9 Msi · Bulk Modulus 70 GPa10.2 Msi · Poisson's Ratio 0.33 · Elongation at Break 4%

Physical

Density and transition temperatures.

Same in both: Density 2.67 g/cm³0.1 lb/in³ · Melting Point (Solidus) 557°C1,035 °F · Liquidus Temperature 613°C1,135 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

157 W/m·K90.7 BTU/hr·ft·°F
151 W/m·K87.2 BTU/hr·ft·°F

Max Service Temperature (continuous)

160°C320 °F
150°C302 °F

Same in both: Specific Heat Capacity 963 J/kg·K0.23 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 21.5 µm/m·K11.9 µin/in·°F · Latent Heat of Fusion 425 J/g183 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

41 % IACS
39 % IACS

Electrical Resistivity

4.2×10⁻⁸ Ω·m1.65 µΩ·in
4.4×10⁻⁸ Ω·m1.73 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.83 V · Corrosion Resistance 58 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

62 / 100
55 / 100

Machinability Rating (AISI 1212 = 100 %)

65%
60%

Weldability

65 / 100
70 / 100

Formability (cold)

10 / 100
15 / 100

Same in both: Castability 90 / 100 · Brazeability / Solderability 30 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 155 MJ/kg66,638 BTU/lb · Embodied Carbon (primary production) 9.5 kg CO₂/kg · Embodied Water 1,100 L/kg132 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scaleEN AC-42200

EN AC-42200-T5 vs EN AC-42200-T6 — frequently asked

Is EN AC-42200-T6 stronger than EN AC-42200-T5?

Yes. EN AC-42200-T6 has a typical yield strength of 250 MPa (36.3 ksi) against 150 MPa (21.8 ksi) for EN AC-42200-T5 — about 67% more. Tensile strength is 320 MPa (46.4 ksi) vs 210 MPa (30.5 ksi).

Which condition does FabDigit quote by default, T5 or T6?

T6 is the default EN AC-42200 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, EN AC-42200-T5 or EN AC-42200-T6?

EN AC-42200-T5, by a small margin. Both rate good for machinability — 62/100 against 55/100 for EN AC-42200-T6; for welding the order is EN AC-42200-T6 first (very good, 70/100) then EN AC-42200-T5 (good, 65/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in EN AC-42200-T5 and EN AC-42200-T6 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.