FabDigitFabDigit

Aluminum EN AC-42100-T5 vs EN AC-42100-T6

Aluminum · EN AC-42100 temper comparison

EN AC-42100-T5 and EN AC-42100-T6 are two conditions of the same aluminum grade, EN AC-42100: T5 (cooled from hot working and artificially aged) versus T6 (solution heat treated and artificially aged). The chemistry is identical, so every difference below comes from the condition. EN AC-42100-T6 is the stronger of the two: yield strength 230 MPa (33.4 ksi) against 125 MPa (18.1 ksi) for EN AC-42100-T5, about 84% more; tensile strength follows at 295 MPa (42.8 ksi) vs 195 MPa (28.3 ksi). EN AC-42100-T6 is the more ductile: elongation 6% versus 3% for EN AC-42100-T5, and EN AC-42100-T6 is harder (95 HB vs 65 HB). EN AC-42100-T5 runs hotter in service (175°C vs 150°C continuous). On the shop floor, EN AC-42100-T6 machines more easily (very good vs good).

EN AC-42100-T5Choose it when the part sees heat.

EN AC-42100-T6Choose it when strength drives the design, or when the part is bent, formed or impact-loaded.

EN AC-42100-T5 vs EN AC-42100-T6: properties

EN AC-42100-T5EN AC-42100-T6

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

72.4 GPa10.5 Msi
72.5 GPa10.5 Msi

Tensile Strength (Ultimate)

195 MPa28.3 ksi
295 MPa42.8 ksi

Yield Strength (0.2% offset)

125 MPa18.1 ksi
230 MPa33.4 ksi

Elongation at Break

3%
6%

Compressive Strength

130 MPa18.9 ksi
235 MPa34.1 ksi

Shear Strength

135 MPa19.6 ksi
195 MPa28.3 ksi

Fatigue Strength (Endurance Limit)

65 MPa9.4 ksi
90 MPa13.1 ksi

Charpy V-Notch Impact (RT)

4 J3 ft·lbf
6 J4.4 ft·lbf

Hardness, Brinell

65 HB
95 HB

Hardness, Vickers

70 HV
100 HV

Same in both: Shear Modulus 27 GPa3.9 Msi · Bulk Modulus 71 GPa10.3 Msi · Poisson's Ratio 0.33 · Fracture Toughness (K_IC) 24 MPa·√m21.8 ksi·√in

Physical

Density and transition temperatures.

Same in both: Density 2.68 g/cm³0.1 lb/in³ · Melting Point (Solidus) 557°C1,035 °F · Liquidus Temperature 613°C1,135 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

159 W/m·K91.9 BTU/hr·ft·°F
151 W/m·K87.2 BTU/hr·ft·°F

Max Service Temperature (continuous)

175°C347 °F
150°C302 °F

Same in both: Specific Heat Capacity 963 J/kg·K0.23 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 21.5 µm/m·K11.9 µin/in·°F · Latent Heat of Fusion 389 J/g167 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

41 % IACS
39 % IACS

Electrical Resistivity

4.2×10⁻⁸ Ω·m1.65 µΩ·in
4.42×10⁻⁸ Ω·m1.74 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

62 / 100
70 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.82 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

55 / 100
70 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 90% · Weldability 75 / 100 · Formability (cold) 15 / 100 · Castability 95 / 100 · Brazeability / Solderability 30 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 155 MJ/kg66,638 BTU/lb · Embodied Carbon (primary production) 10.5 kg CO₂/kg · Embodied Water 1,100 L/kg132 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scaleEN AC-42100

EN AC-42100-T5 vs EN AC-42100-T6 — frequently asked

Is EN AC-42100-T6 stronger than EN AC-42100-T5?

Yes. EN AC-42100-T6 has a typical yield strength of 230 MPa (33.4 ksi) against 125 MPa (18.1 ksi) for EN AC-42100-T5 — about 84% more. Tensile strength is 295 MPa (42.8 ksi) vs 195 MPa (28.3 ksi).

Which condition does FabDigit quote by default, T5 or T6?

T6 is the default EN AC-42100 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, EN AC-42100-T5 or EN AC-42100-T6?

EN AC-42100-T6. Its machinability rates very good (70/100) against good (55/100) for EN AC-42100-T5.

Ready to make it?

Upload a CAD file and FabDigit prices the part in EN AC-42100-T5 and EN AC-42100-T6 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.