FabDigitFabDigit

Aluminum EN AC-42100-F vs EN AC-42100-T6

Aluminum · EN AC-42100 temper comparison

EN AC-42100-F and EN AC-42100-T6 are two conditions of the same aluminum grade, EN AC-42100: F (as fabricated) versus T6 (solution heat treated and artificially aged). The chemistry is identical, so every difference below comes from the condition. EN AC-42100-T6 is the stronger of the two: yield strength 230 MPa (33.4 ksi) against 85 MPa (12.3 ksi) for EN AC-42100-F, about 171% more; tensile strength follows at 295 MPa (42.8 ksi) vs 170 MPa (24.7 ksi). EN AC-42100-T6 is the more ductile: elongation 6% versus 4% for EN AC-42100-F, and EN AC-42100-T6 is harder (95 HB vs 55 HB). EN AC-42100-F runs hotter in service (200°C vs 150°C continuous). On the shop floor, EN AC-42100-T6 machines more easily (very good vs fair).

EN AC-42100-FChoose it when the part sees heat.

EN AC-42100-T6Choose it when strength drives the design, or when the part is bent, formed or impact-loaded.

EN AC-42100-F vs EN AC-42100-T6: properties

EN AC-42100-FEN AC-42100-T6

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

170 MPa24.7 ksi
295 MPa42.8 ksi

Yield Strength (0.2% offset)

85 MPa12.3 ksi
230 MPa33.4 ksi

Elongation at Break

4%
6%

Shear Strength

125 MPa18.1 ksi
195 MPa28.3 ksi

Fatigue Strength (Endurance Limit)

55 MPa8 ksi
90 MPa13.1 ksi

Hardness, Brinell

55 HB
95 HB

Same in both: Elastic (Young's) Modulus 72.5 GPa10.5 Msi · Shear Modulus 27 GPa3.9 Msi · Bulk Modulus 71 GPa10.3 Msi · Poisson's Ratio 0.33 · Compressive Strength 235 MPa34.1 ksi · Fracture Toughness (K_IC) 24 MPa·√m21.8 ksi·√in · Charpy V-Notch Impact (RT) 6 J4.4 ft·lbf · Hardness, Vickers 100 HV

Physical

Density and transition temperatures.

Same in both: Density 2.68 g/cm³0.1 lb/in³ · Melting Point (Solidus) 557°C1,035 °F · Liquidus Temperature 613°C1,135 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

167 W/m·K96.5 BTU/hr·ft·°F
151 W/m·K87.2 BTU/hr·ft·°F

Max Service Temperature (continuous)

200°C392 °F
150°C302 °F

Same in both: Specific Heat Capacity 963 J/kg·K0.23 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 21.5 µm/m·K11.9 µin/in·°F · Latent Heat of Fusion 389 J/g167 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

43 % IACS
39 % IACS

Same in both: Electrical Resistivity 4.42×10⁻⁸ Ω·m1.74 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

62 / 100
70 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.82 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

52 / 100
70 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 90% · Weldability 75 / 100 · Formability (cold) 15 / 100 · Castability 95 / 100 · Brazeability / Solderability 30 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 155 MJ/kg66,638 BTU/lb · Embodied Carbon (primary production) 10.5 kg CO₂/kg · Embodied Water 1,100 L/kg132 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scaleEN AC-42100

EN AC-42100-F vs EN AC-42100-T6 — frequently asked

Is EN AC-42100-T6 stronger than EN AC-42100-F?

Yes. EN AC-42100-T6 has a typical yield strength of 230 MPa (33.4 ksi) against 85 MPa (12.3 ksi) for EN AC-42100-F — about 171% more. Tensile strength is 295 MPa (42.8 ksi) vs 170 MPa (24.7 ksi).

Which condition does FabDigit quote by default, F or T6?

T6 is the default EN AC-42100 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, EN AC-42100-F or EN AC-42100-T6?

EN AC-42100-T6. Its machinability rates very good (70/100) against fair (52/100) for EN AC-42100-F.

Ready to make it?

Upload a CAD file and FabDigit prices the part in EN AC-42100-F and EN AC-42100-T6 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.