FabDigitFabDigit

Aluminum EN AC-42100-F vs EN AC-42100-T61

Aluminum · EN AC-42100 temper comparison

EN AC-42100-F and EN AC-42100-T61 are two conditions of the same aluminum grade, EN AC-42100: F (as fabricated) versus T61 (T6 variant, underaged). The chemistry is identical, so every difference below comes from the condition. EN AC-42100-T61 is the stronger of the two: yield strength 207 MPa (30 ksi) against 85 MPa (12.3 ksi) for EN AC-42100-F, about 144% more; tensile strength follows at 283 MPa (41 ksi) vs 170 MPa (24.7 ksi). EN AC-42100-T61 is the more ductile: elongation 10% versus 4% for EN AC-42100-F, and EN AC-42100-T61 is harder (90 HB vs 55 HB). EN AC-42100-F runs hotter in service (200°C vs 150°C continuous).

EN AC-42100-FChoose it when the part sees heat.

EN AC-42100-T61Choose it when strength drives the design, or when the part is bent, formed or impact-loaded.

EN AC-42100-F vs EN AC-42100-T61: properties

EN AC-42100-FEN AC-42100-T61

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

170 MPa24.7 ksi
283 MPa41 ksi

Yield Strength (0.2% offset)

85 MPa12.3 ksi
207 MPa30 ksi

Elongation at Break

4%
10%

Shear Strength

125 MPa18.1 ksi
190 MPa27.6 ksi

Fatigue Strength (Endurance Limit)

55 MPa8 ksi
95 MPa13.8 ksi

Hardness, Brinell

55 HB
90 HB

Same in both: Elastic (Young's) Modulus 72.5 GPa10.5 Msi · Shear Modulus 27 GPa3.9 Msi · Bulk Modulus 71 GPa10.3 Msi · Poisson's Ratio 0.33 · Compressive Strength 235 MPa34.1 ksi · Fracture Toughness (K_IC) 24 MPa·√m21.8 ksi·√in · Charpy V-Notch Impact (RT) 6 J4.4 ft·lbf · Hardness, Vickers 100 HV

Physical

Density and transition temperatures.

Same in both: Density 2.68 g/cm³0.1 lb/in³ · Melting Point (Solidus) 557°C1,035 °F · Liquidus Temperature 613°C1,135 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

167 W/m·K96.5 BTU/hr·ft·°F
159 W/m·K91.9 BTU/hr·ft·°F

Max Service Temperature (continuous)

200°C392 °F
150°C302 °F

Same in both: Specific Heat Capacity 963 J/kg·K0.23 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 21.5 µm/m·K11.9 µin/in·°F · Latent Heat of Fusion 389 J/g167 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

43 % IACS
40 % IACS

Same in both: Electrical Resistivity 4.42×10⁻⁸ Ω·m1.74 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

62 / 100
70 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.82 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

52 / 100
60 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 90% · Weldability 75 / 100 · Formability (cold) 15 / 100 · Castability 95 / 100 · Brazeability / Solderability 30 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 155 MJ/kg66,638 BTU/lb · Embodied Carbon (primary production) 10.5 kg CO₂/kg · Embodied Water 1,100 L/kg132 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scaleEN AC-42100

EN AC-42100-F vs EN AC-42100-T61 — frequently asked

Is EN AC-42100-T61 stronger than EN AC-42100-F?

Yes. EN AC-42100-T61 has a typical yield strength of 207 MPa (30 ksi) against 85 MPa (12.3 ksi) for EN AC-42100-F — about 144% more. Tensile strength is 283 MPa (41 ksi) vs 170 MPa (24.7 ksi).

Which condition does FabDigit quote by default, F or T61?

T6 is the default EN AC-42100 condition in the FabDigit quote flow (neither F nor T61). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, EN AC-42100-F or EN AC-42100-T61?

EN AC-42100-T61. Its machinability rates good (60/100) against fair (52/100) for EN AC-42100-F.

Ready to make it?

Upload a CAD file and FabDigit prices the part in EN AC-42100-F and EN AC-42100-T61 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.