FabDigitFabDigit

Aluminum AC1B-T4 vs AC1B-T6

Aluminum · AC1B temper comparison

AC1B-T4 and AC1B-T6 are two conditions of the same aluminum grade, AC1B: T4 (solution heat treated and naturally aged) versus T6 (solution heat treated and artificially aged). The chemistry is identical, so every difference below comes from the condition. AC1B-T6 is the stronger of the two: yield strength 250 MPa (36.3 ksi) against 190 MPa (27.6 ksi) for AC1B-T4, about 32% more; tensile strength follows at 350 MPa (50.8 ksi) vs 320 MPa (46.4 ksi). In exchange, AC1B-T4 is the more ductile: elongation 12% versus 6% for AC1B-T6, and AC1B-T6 is harder (100 HB vs 85 HB). AC1B-T6 runs hotter in service (200°C vs 150°C continuous).

AC1B-T4Choose it when the part is bent, formed or impact-loaded.

AC1B-T6Choose it when strength drives the design, or when the part sees heat.

AC1B-T4 vs AC1B-T6: properties

AC1B-T4AC1B-T6

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

320 MPa46.4 ksi
350 MPa50.8 ksi

Yield Strength (0.2% offset)

190 MPa27.6 ksi
250 MPa36.3 ksi

Elongation at Break

12%
6%

Shear Strength

200 MPa29 ksi
220 MPa31.9 ksi

Fatigue Strength (Endurance Limit)

85 MPa12.3 ksi
90 MPa13.1 ksi

Charpy V-Notch Impact (RT)

14 J10.3 ft·lbf
8 J5.9 ft·lbf

Hardness, Brinell

85 HB
100 HB

Same in both: Elastic (Young's) Modulus 71 GPa10.3 Msi · Shear Modulus 26.5 GPa3.8 Msi · Bulk Modulus 71 GPa10.3 Msi · Poisson's Ratio 0.33 · Compressive Strength 260 MPa37.7 ksi · Fracture Toughness (K_IC) 24 MPa·√m21.8 ksi·√in

Physical

Density and transition temperatures.

Same in both: Density 2.8 g/cm³0.1 lb/in³ · Melting Point (Solidus) 545°C1,013 °F · Liquidus Temperature 645°C1,193 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

125 W/m·K72.2 BTU/hr·ft·°F
130 W/m·K75.1 BTU/hr·ft·°F

Max Service Temperature (continuous)

150°C302 °F
200°C392 °F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 22.5 µm/m·K12.5 µin/in·°F · Latent Heat of Fusion 390 J/g168 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

30 % IACS
33 % IACS

Same in both: Electrical Resistivity 5.2×10⁻⁸ Ω·m2.05 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.7 V · Corrosion Resistance 35 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

78 / 100
80 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 300% · Weldability 30 / 100 · Castability 40 / 100 · Brazeability / Solderability 20 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,100 L/kg132 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scaleAC1B

AC1B-T4 vs AC1B-T6 — frequently asked

Is AC1B-T6 stronger than AC1B-T4?

Yes. AC1B-T6 has a typical yield strength of 250 MPa (36.3 ksi) against 190 MPa (27.6 ksi) for AC1B-T4 — about 32% more. Tensile strength is 350 MPa (50.8 ksi) vs 320 MPa (46.4 ksi).

Which condition does FabDigit quote by default, T4 or T6?

T6 is the default AC1B condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose AC1B-T4 over AC1B-T6?

Pick AC1B-T4 when the part is bent, formed or impact-loaded. Pick AC1B-T6 when strength drives the design, or when the part sees heat.

Ready to make it?

Upload a CAD file and FabDigit prices the part in AC1B-T4 and AC1B-T6 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.