FabDigitFabDigit

Aluminum AC1B-T4 vs AC1B-T7

Aluminum · AC1B temper comparison

AC1B-T4 and AC1B-T7 are two conditions of the same aluminum grade, AC1B: T4 (solution heat treated and naturally aged) versus T7 (solution heat treated and overaged (stabilized)). The chemistry is identical, so every difference below comes from the condition. AC1B-T7 is the stronger of the two: yield strength 230 MPa (33.4 ksi) against 190 MPa (27.6 ksi) for AC1B-T4, about 21% more. In exchange, AC1B-T4 is the more ductile: elongation 12% versus 5% for AC1B-T7, and AC1B-T7 is harder (90 HB vs 85 HB). AC1B-T7 runs hotter in service (250°C vs 150°C continuous) and AC1B-T7 conducts heat better (140 W/m·K vs 125 W/m·K).

AC1B-T4Choose it when the part is bent, formed or impact-loaded.

AC1B-T7Choose it when strength drives the design, or when the part sees heat.

AC1B-T4 vs AC1B-T7: properties

AC1B-T4AC1B-T7

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

320 MPa46.4 ksi
300 MPa43.5 ksi

Yield Strength (0.2% offset)

190 MPa27.6 ksi
230 MPa33.4 ksi

Elongation at Break

12%
5%

Shear Strength

200 MPa29 ksi
220 MPa31.9 ksi

Charpy V-Notch Impact (RT)

14 J10.3 ft·lbf
8 J5.9 ft·lbf

Hardness, Brinell

85 HB
90 HB

Same in both: Elastic (Young's) Modulus 71 GPa10.3 Msi · Shear Modulus 26.5 GPa3.8 Msi · Bulk Modulus 71 GPa10.3 Msi · Poisson's Ratio 0.33 · Compressive Strength 260 MPa37.7 ksi · Fatigue Strength (Endurance Limit) 85 MPa12.3 ksi · Fracture Toughness (K_IC) 24 MPa·√m21.8 ksi·√in

Physical

Density and transition temperatures.

Same in both: Density 2.8 g/cm³0.1 lb/in³ · Melting Point (Solidus) 545°C1,013 °F · Liquidus Temperature 645°C1,193 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

125 W/m·K72.2 BTU/hr·ft·°F
140 W/m·K80.9 BTU/hr·ft·°F

Max Service Temperature (continuous)

150°C302 °F
250°C482 °F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 22.5 µm/m·K12.5 µin/in·°F · Latent Heat of Fusion 390 J/g168 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

30 % IACS
36 % IACS

Same in both: Electrical Resistivity 5.2×10⁻⁸ Ω·m2.05 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

35 / 100
42 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.7 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Same in both: Machinability 78 / 100 · Machinability Rating (AISI 1212 = 100 %) 300% · Weldability 30 / 100 · Castability 40 / 100 · Brazeability / Solderability 20 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,100 L/kg132 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scaleAC1B

AC1B-T4 vs AC1B-T7 — frequently asked

Is AC1B-T7 stronger than AC1B-T4?

Yes. AC1B-T7 has a typical yield strength of 230 MPa (33.4 ksi) against 190 MPa (27.6 ksi) for AC1B-T4 — about 21% more. Tensile strength is 300 MPa (43.5 ksi) vs 320 MPa (46.4 ksi).

Which condition does FabDigit quote by default, T4 or T7?

T6 is the default AC1B condition in the FabDigit quote flow (neither T4 nor T7). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose AC1B-T4 over AC1B-T7?

Pick AC1B-T4 when the part is bent, formed or impact-loaded. Pick AC1B-T7 when strength drives the design, or when the part sees heat.

Ready to make it?

Upload a CAD file and FabDigit prices the part in AC1B-T4 and AC1B-T7 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.