FabDigitFabDigit

Aluminum A1N00-H22 vs A1N00-H24

Aluminum · A1N00 temper comparison

A1N00-H22 and A1N00-H24 are two conditions of the same aluminum grade, A1N00: H22 (strain hardened and partially annealed, quarter hard) versus H24 (strain hardened and partially annealed, half hard). The chemistry is identical, so every difference below comes from the condition. A1N00-H24 is the stronger of the two: yield strength 100 MPa (14.5 ksi) against 85 MPa (12.3 ksi) for A1N00-H22, about 18% more; tensile strength follows at 125 MPa (18.1 ksi) vs 110 MPa (16 ksi). In exchange, A1N00-H22 is the more ductile: elongation 16% versus 12% for A1N00-H24, and A1N00-H24 is harder (32 HB vs 28 HB).

A1N00-H22Choose it when the part is bent, formed or impact-loaded.

A1N00-H24Choose it when strength drives the design.

A1N00-H22 vs A1N00-H24: properties

A1N00-H22A1N00-H24

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

110 MPa16 ksi
125 MPa18.1 ksi

Yield Strength (0.2% offset)

85 MPa12.3 ksi
100 MPa14.5 ksi

Elongation at Break

16%
12%

Reduction in Area

65%
55%

Shear Strength

70 MPa10.2 ksi
75 MPa10.9 ksi

Fatigue Strength (Endurance Limit)

40 MPa5.8 ksi
45 MPa6.5 ksi

Hardness, Brinell

28 HB
32 HB

Same in both: Elastic (Young's) Modulus 69 GPa10 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 75 GPa10.9 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.71 g/cm³0.1 lb/in³ · Melting Point (Solidus) 643°C1,189 °F · Liquidus Temperature 657°C1,215 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

150°C302 °F
140°C284 °F

Same in both: Thermal Conductivity 220 W/m·K127 BTU/hr·ft·°F · Specific Heat Capacity 904 J/kg·K0.22 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.6 µm/m·K13.1 µin/in·°F · Latent Heat of Fusion 397 J/g171 BTU/lb · Min Service Temperature -269°C-452 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 58.5 % IACS · Electrical Resistivity 2.95×10⁻⁸ Ω·m1.16 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.83 V · Corrosion Resistance 72 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

28 / 100
30 / 100

Machinability Rating (AISI 1212 = 100 %)

28%
30%

Formability (cold)

90 / 100
84 / 100

Same in both: Weldability 92 / 100 · Brazeability / Solderability 90 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 205 MJ/kg88,134 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,100 L/kg132 gal/lb · Typical Recycled Content 20%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scaleA1N00

A1N00-H22 vs A1N00-H24 — frequently asked

Is A1N00-H24 stronger than A1N00-H22?

Yes. A1N00-H24 has a typical yield strength of 100 MPa (14.5 ksi) against 85 MPa (12.3 ksi) for A1N00-H22 — about 18% more. Tensile strength is 125 MPa (18.1 ksi) vs 110 MPa (16 ksi).

Which condition does FabDigit quote by default, H22 or H24?

O is the default A1N00 condition in the FabDigit quote flow (neither H22 nor H24). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose A1N00-H22 over A1N00-H24?

Pick A1N00-H22 when the part is bent, formed or impact-loaded. Pick A1N00-H24 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in A1N00-H22 and A1N00-H24 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.