FabDigitFabDigit

Aluminum A1N00-F vs A1N00-H26

Aluminum · A1N00 temper comparison

A1N00-F and A1N00-H26 are two conditions of the same aluminum grade, A1N00: F (as fabricated) versus H26 (strain hardened and partially annealed, three-quarter hard). The chemistry is identical, so every difference below comes from the condition. A1N00-H26 is the stronger of the two: yield strength 125 MPa (18.1 ksi) against 45 MPa (6.53 ksi) for A1N00-F, about 178% more; tensile strength follows at 145 MPa (21 ksi) vs 95 MPa (13.8 ksi). In exchange, A1N00-F is the more ductile: elongation 30% versus 8% for A1N00-H26, and A1N00-H26 is harder (38 HB vs 25 HB). A1N00-F runs hotter in service (200°C vs 130°C continuous).

A1N00-FChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

A1N00-H26Choose it when strength drives the design.

A1N00-F vs A1N00-H26: properties

A1N00-FA1N00-H26

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

95 MPa13.8 ksi
145 MPa21 ksi

Yield Strength (0.2% offset)

45 MPa6.5 ksi
125 MPa18.1 ksi

Elongation at Break

30%
8%

Reduction in Area

75%
45%

Shear Strength

65 MPa9.4 ksi
85 MPa12.3 ksi

Fatigue Strength (Endurance Limit)

35 MPa5.1 ksi
48 MPa7 ksi

Hardness, Brinell

25 HB
38 HB

Same in both: Elastic (Young's) Modulus 69 GPa10 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 75 GPa10.9 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.71 g/cm³0.1 lb/in³ · Melting Point (Solidus) 643°C1,189 °F · Liquidus Temperature 657°C1,215 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

222 W/m·K128 BTU/hr·ft·°F
218 W/m·K126 BTU/hr·ft·°F

Max Service Temperature (continuous)

200°C392 °F
130°C266 °F

Same in both: Specific Heat Capacity 904 J/kg·K0.22 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.6 µm/m·K13.1 µin/in·°F · Latent Heat of Fusion 397 J/g171 BTU/lb · Min Service Temperature -269°C-452 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

59 % IACS
58 % IACS

Electrical Resistivity

2.92×10⁻⁸ Ω·m1.15 µΩ·in
2.97×10⁻⁸ Ω·m1.17 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.83 V · Corrosion Resistance 72 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

26 / 100
32 / 100

Machinability Rating (AISI 1212 = 100 %)

26%
32%

Weldability

92 / 100
90 / 100

Formability (cold)

93 / 100
70 / 100

Same in both: Brazeability / Solderability 90 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 205 MJ/kg88,134 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,100 L/kg132 gal/lb · Typical Recycled Content 20%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scaleA1N00

A1N00-F vs A1N00-H26 — frequently asked

Is A1N00-H26 stronger than A1N00-F?

Yes. A1N00-H26 has a typical yield strength of 125 MPa (18.1 ksi) against 45 MPa (6.53 ksi) for A1N00-F — about 178% more. Tensile strength is 145 MPa (21 ksi) vs 95 MPa (13.8 ksi).

Which condition does FabDigit quote by default, F or H26?

O is the default A1N00 condition in the FabDigit quote flow (neither F nor H26). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, A1N00-F or A1N00-H26?

A1N00-H26, by a small margin. Both rate poor for machinability — 32/100 against 26/100 for A1N00-F.

Ready to make it?

Upload a CAD file and FabDigit prices the part in A1N00-F and A1N00-H26 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.