Aluminum · grade comparison

Aluminum 6060 and 6182 are both aluminum grades. 6182 is the stronger of the two: yield strength 290 MPa (42.1 ksi) against 170 MPa (24.7 ksi) for 6060, about 71% more; tensile strength follows at 330 MPa (47.9 ksi) vs 215 MPa (31.2 ksi). In exchange, 6060 is the more ductile: elongation 12% versus 10% for 6182, and 6182 is harder (98 HB vs 75 HB). 6060 conducts heat better (200 W/m·K vs 170 W/m·K). On the shop floor, 6060 welds better (excellent vs very good) and 6060 sits in a lower cost tier (budget, $) than 6182 (standard, $$).

6060Choose it when the part is bent, formed or impact-loaded, or when it will be welded.

6182Choose it when strength drives the design.

6060 vs 6182: properties

60606182

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

69 GPa10 Msi
69.5 GPa10.1 Msi

Tensile Strength (Ultimate)

215 MPa31.2 ksi
330 MPa47.9 ksi

Yield Strength (0.2% offset)

170 MPa24.7 ksi
290 MPa42.1 ksi

Elongation at Break

12%
10%

Shear Strength

140 MPa20.3 ksi
205 MPa29.7 ksi

Fatigue Strength (Endurance Limit)

60 MPa8.7 ksi
95 MPa13.8 ksi

Fracture Toughness (K_IC)

30 MPa·√m27.3 ksi·√in
29 MPa·√m26.4 ksi·√in

Hardness, Brinell

75 HB
98 HB

Hardness, Vickers

80 HV
105 HV

Charpy V-Notch Impact (RT)

—
18 J13.3 ft·lbf

Hardness, Rockwell B

—
60 HRB

Same in both: Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 69 GPa10 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Melting Point (Solidus)

600°C1,112 °F
585°C1,085 °F

Liquidus Temperature

655°C1,211 °F
650°C1,202 °F

Same in both: Density 2.7 g/cm³0.1 lb/in³

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

200 W/m·K116 BTU/hr·ft·°F
170 W/m·K98.2 BTU/hr·ft·°F

Specific Heat Capacity

898 J/kg·K0.21 BTU/lb·°F
900 J/kg·K0.21 BTU/lb·°F

Latent Heat of Fusion

397 J/g171 BTU/lb
393 J/g169 BTU/lb

Same in both: Thermal Expansion (CTE, 20–100 °C) 23.4 µm/m·K13 µin/in·°F · Max Service Temperature (continuous) 150°C302 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

54 % IACS
42 % IACS

Electrical Resistivity

3.2×10⁻⁸ Ω·m1.26 µΩ·in
4.1×10⁻⁸ Ω·m1.61 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Galvanic Potential (seawater, vs SCE)

-0.83 V
-0.74 V

Corrosion Resistance

68 / 100
65 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

55 / 100
58 / 100

Weldability

90 / 100
72 / 100

Formability (cold)

55 / 100
45 / 100

Castability

25 / 100
35 / 100

Brazeability / Solderability

60 / 100
45 / 100

Polishability

80 / 100
70 / 100

Machinability Rating (AISI 1212 = 100 %)

—
150%

Sustainability

Primary-production footprint per kilogram.

Embodied Carbon (primary production)

13 kg CO₂/kg
12.5 kg CO₂/kg

Embodied Water

1,200 L/kg144 gal/lb
1,150 L/kg138 gal/lb

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Typical Recycled Content 35%

Common Calculations

Ratios derived from the values above.

Specific Strength (UTS / density)

80 kN·m/kg
122 kN·m/kg

Specific Stiffness (E / density)

25.6 MN·m/kg
25.7 MN·m/kg

Modulus of Resilience

209 kJ/m³
605 kJ/m³

Thermal Diffusivity

82.5 mm²/s
70 mm²/s

Thermal Shock Resistance Index

27
34

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale60606182

Manufacturing and finishing

Capability60606182
CNC machiningYes—
Sheet metalYes—
Default condition——
Relative cost$ Budget$$ Standard
Min. machined wall0.5 mm—
Best machined surfaceRa 0.8 µm—
Anodizing Type IIYes—
CerakoteYes—
Chem Film (Alodine)Yes—
DLCYes—
E-CoatingYes—
ElectropolishingYes—
Hard Anodize Type III w/ PTFEYes—
Hard Anodizing Type IIIYes—
Nickel PlatingYes—
PTFE CoatingYes—
PaintingYes—
Powder CoatingYes—

They share 4 finishes: Electroless Nickel (EN), Epoxy Coating, Gold Plating, Silver Plating.

6060 vs 6182 — frequently asked

Is 6182 stronger than 6060?

Yes. 6182 has a typical yield strength of 290 MPa (42.1 ksi) against 170 MPa (24.7 ksi) for 6060 — about 71% more. Tensile strength is 330 MPa (47.9 ksi) vs 215 MPa (31.2 ksi).

Which is cheaper, 6060 or 6182?

6060 is the lower-cost material: it sits in the budget tier ($) while 6182 is standard ($$). Part price depends far more on geometry, tolerance and quantity than on raw stock — upload a CAD file for a live quote.

Which welds better, 6060 or 6182?

6060. Its weldability rates excellent (90/100) against very good (72/100) for 6182.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 6060 and 6182 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.