FabDigitFabDigit

Aluminum 6060 vs 6111

Aluminum · grade comparison

Aluminum 6060 and 6111 are both aluminum grades. 6060 is the stronger of the two: yield strength 170 MPa (24.7 ksi) against 160 MPa (23.2 ksi) for 6111, about 6% more. In exchange, 6111 is the more ductile: elongation 26% versus 12% for 6060. 6060 runs hotter in service (150°C vs 120°C continuous) and 6060 conducts heat better (200 W/m·K vs 165 W/m·K). On the shop floor, 6111 machines more easily (65 vs 55 out of 100), 6060 welds better (excellent vs good), and 6060 sits in a lower cost tier (budget, $) than 6111 (standard, $$).

6060Choose it when strength drives the design, or when the part sees heat.

6111Choose it when the part is bent, formed or impact-loaded, or when the part is machined in volume.

6060 vs 6111: properties

60606111

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

69 GPa10 Msi
70 GPa10.2 Msi

Tensile Strength (Ultimate)

215 MPa31.2 ksi
295 MPa42.8 ksi

Yield Strength (0.2% offset)

170 MPa24.7 ksi
160 MPa23.2 ksi

Elongation at Break

12%
26%

Shear Strength

140 MPa20.3 ksi
190 MPa27.6 ksi

Fatigue Strength (Endurance Limit)

60 MPa8.7 ksi
100 MPa14.5 ksi

Hardness, Brinell

75 HB
78 HB

Hardness, Vickers

80 HV
—

Compressive Strength

—
160 MPa23.2 ksi

Same in both: Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 69 GPa10 Msi · Poisson's Ratio 0.33 · Fracture Toughness (K_IC) 30 MPa·√m27.3 ksi·√in

Physical

Density and transition temperatures.

Density

2.7 g/cm³0.1 lb/in³
2.71 g/cm³0.1 lb/in³

Melting Point (Solidus)

600°C1,112 °F
560°C1,040 °F

Liquidus Temperature

655°C1,211 °F
650°C1,202 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

200 W/m·K116 BTU/hr·ft·°F
165 W/m·K95.3 BTU/hr·ft·°F

Specific Heat Capacity

898 J/kg·K0.21 BTU/lb·°F
895 J/kg·K0.21 BTU/lb·°F

Thermal Expansion (CTE, 20–100 °C)

23.4 µm/m·K13 µin/in·°F
23.5 µm/m·K13.1 µin/in·°F

Latent Heat of Fusion

397 J/g171 BTU/lb
390 J/g168 BTU/lb

Max Service Temperature (continuous)

150°C302 °F
120°C248 °F

Same in both: Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

54 % IACS
40 % IACS

Electrical Resistivity

3.2×10⁻⁸ Ω·m1.26 µΩ·in
4.3×10⁻⁸ Ω·m1.69 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Galvanic Potential (seawater, vs SCE)

-0.83 V
-0.74 V

Corrosion Resistance

68 / 100
58 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

55 / 100
65 / 100

Weldability

90 / 100
55 / 100

Formability (cold)

55 / 100
80 / 100

Castability

25 / 100
—

Brazeability / Solderability

60 / 100
30 / 100

Polishability

80 / 100
60 / 100

Machinability Rating (AISI 1212 = 100 %)

—
60%

Sustainability

Primary-production footprint per kilogram.

Embodied Carbon (primary production)

13 kg CO₂/kg
12 kg CO₂/kg

Typical Recycled Content

35%
25%

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Water 1,200 L/kg144 gal/lb

Common Calculations

Ratios derived from the values above.

Specific Strength (UTS / density)

80 kN·m/kg
109 kN·m/kg

Specific Stiffness (E / density)

25.6 MN·m/kg
25.8 MN·m/kg

Modulus of Resilience

209 kJ/m³
183 kJ/m³

Thermal Diffusivity

82.5 mm²/s
68 mm²/s

Thermal Shock Resistance Index

27
30

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale60606111

Manufacturing and finishing

Capability60606111
CNC machiningYes—
Default condition—T4
Relative cost$ Budget$$ Standard
Min. machined wall0.5 mm—
Best machined surfaceRa 0.8 µm—
DLCYes—

Both are offered for Sheet metal. They share 15 finishes: Anodizing Type II, Cerakote, Chem Film (Alodine), E-Coating, Electroless Nickel (EN), Electropolishing, Epoxy Coating, Gold Plating, Hard Anodize Type III w/ PTFE, Hard Anodizing Type III, Nickel Plating, PTFE Coating and 3 more.

6060 vs 6111 — frequently asked

Is 6060 stronger than 6111?

Yes. 6060 has a typical yield strength of 170 MPa (24.7 ksi) against 160 MPa (23.2 ksi) for 6111 — about 6% more. Tensile strength is 215 MPa (31.2 ksi) vs 295 MPa (42.8 ksi).

Which is cheaper, 6060 or 6111?

6060 is the lower-cost material: it sits in the budget tier ($) while 6111 is standard ($$). Part price depends far more on geometry, tolerance and quantity than on raw stock — upload a CAD file for a live quote.

Which is easier to machine, 6060 or 6111?

6111, by a small margin. Both rate good for machinability — 65/100 against 55/100 for 6060; for welding the order is 6060 first (excellent, 90/100) then 6111 (good, 55/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 6060 and 6111 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.