FabDigitFabDigit

Aluminum 6009-T4 vs 6009-T6

Aluminum · 6009 temper comparison

6009-T4 and 6009-T6 are two conditions of the same aluminum grade, 6009: T4 (solution heat treated and naturally aged) versus T6 (solution heat treated and artificially aged). The chemistry is identical, so every difference below comes from the condition. 6009-T6 is the stronger of the two: yield strength 234 MPa (33.9 ksi) against 131 MPa (19 ksi) for 6009-T4, about 79% more; tensile strength follows at 262 MPa (38 ksi) vs 234 MPa (33.9 ksi). In exchange, 6009-T4 is the more ductile: elongation 25% versus 12% for 6009-T6, and 6009-T6 is harder (85 HB vs 62 HB). 6009-T6 runs hotter in service (150°C vs 120°C continuous). On the shop floor, 6009-T6 machines more easily (good vs fair).

6009-T4Choose it when the part is bent, formed or impact-loaded.

6009-T6Choose it when strength drives the design, or when the part sees heat.

6009-T4 vs 6009-T6: properties

6009-T46009-T6

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

234 MPa33.9 ksi
262 MPa38 ksi

Yield Strength (0.2% offset)

131 MPa19 ksi
234 MPa33.9 ksi

Elongation at Break

25%
12%

Shear Strength

152 MPa22 ksi
165 MPa23.9 ksi

Fatigue Strength (Endurance Limit)

110 MPa16 ksi
117 MPa17 ksi

Hardness, Brinell

62 HB
85 HB

Hardness, Rockwell B

30 HRB
52 HRB

Same in both: Elastic (Young's) Modulus 69 GPa10 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 70 GPa10.2 Msi · Poisson's Ratio 0.33 · Fracture Toughness (K_IC) 35 MPa·√m31.9 ksi·√in

Physical

Density and transition temperatures.

Same in both: Density 2.71 g/cm³0.1 lb/in³ · Melting Point (Solidus) 560°C1,040 °F · Liquidus Temperature 650°C1,202 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

172 W/m·K99.4 BTU/hr·ft·°F
180 W/m·K104 BTU/hr·ft·°F

Max Service Temperature (continuous)

120°C248 °F
150°C302 °F

Same in both: Specific Heat Capacity 897 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.4 µm/m·K13 µin/in·°F · Latent Heat of Fusion 395 J/g170 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

44 % IACS
47 % IACS

Same in both: Electrical Resistivity 3.9×10⁻⁸ Ω·m1.54 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.77 V · Corrosion Resistance 58 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

45 / 100
58 / 100

Formability (cold)

80 / 100
45 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 30% · Weldability 70 / 100 · Brazeability / Solderability 35 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale6009

6009-T4 vs 6009-T6 — frequently asked

Is 6009-T6 stronger than 6009-T4?

Yes. 6009-T6 has a typical yield strength of 234 MPa (33.9 ksi) against 131 MPa (19 ksi) for 6009-T4 — about 79% more. Tensile strength is 262 MPa (38 ksi) vs 234 MPa (33.9 ksi).

Which condition does FabDigit quote by default, T4 or T6?

T4 is the default 6009 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 6009-T4 or 6009-T6?

6009-T6. Its machinability rates good (58/100) against fair (45/100) for 6009-T4.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 6009-T4 and 6009-T6 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.