FabDigitFabDigit

Aluminum 5082-H14 vs 5082-O

Aluminum · 5082 temper comparison

5082-H14 and 5082-O are two conditions of the same aluminum grade, 5082: H14 (strain hardened, half hard) versus O (annealed). The chemistry is identical, so every difference below comes from the condition. 5082-H14 is the stronger of the two: yield strength 260 MPa (37.7 ksi) against 125 MPa (18.1 ksi) for 5082-O, about 108% more; tensile strength follows at 330 MPa (47.9 ksi) vs 265 MPa (38.4 ksi). In exchange, 5082-O is the more ductile: elongation 24% versus 9% for 5082-H14, and 5082-H14 is harder (85 HB vs 62 HB). On the shop floor, 5082-H14 machines more easily (good vs fair).

5082-H14Choose it when strength drives the design, or when the part is machined in volume.

5082-OChoose it when the part is bent, formed or impact-loaded.

5082-H14 vs 5082-O: properties

5082-H145082-O

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

330 MPa47.9 ksi
265 MPa38.4 ksi

Yield Strength (0.2% offset)

260 MPa37.7 ksi
125 MPa18.1 ksi

Elongation at Break

9%
24%

Shear Strength

195 MPa28.3 ksi
165 MPa23.9 ksi

Fatigue Strength (Endurance Limit)

155 MPa22.5 ksi
135 MPa19.6 ksi

Fracture Toughness (K_IC)

28 MPa·√m25.5 ksi·√in
40 MPa·√m36.4 ksi·√in

Hardness, Brinell

85 HB
62 HB

Same in both: Elastic (Young's) Modulus 70 GPa10.2 Msi · Shear Modulus 26.4 GPa3.8 Msi · Bulk Modulus 69 GPa10 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.65 g/cm³0.1 lb/in³ · Melting Point (Solidus) 577°C1,071 °F · Liquidus Temperature 638°C1,180 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

117 W/m·K67.6 BTU/hr·ft·°F
123 W/m·K71.1 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 24.2 µm/m·K13.4 µin/in·°F · Latent Heat of Fusion 395 J/g170 BTU/lb · Max Service Temperature (continuous) 65°C149 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

29 % IACS
29.5 % IACS

Electrical Resistivity

5.9×10⁻⁸ Ω·m2.32 µΩ·in
5.85×10⁻⁸ Ω·m2.3 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

70 / 100
76 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.87 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

55 / 100
40 / 100

Machinability Rating (AISI 1212 = 100 %)

37%
25%

Weldability

85 / 100
90 / 100

Formability (cold)

58 / 100
92 / 100

Same in both: Brazeability / Solderability 20 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,100 L/kg132 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale5082

5082-H14 vs 5082-O — frequently asked

Is 5082-H14 stronger than 5082-O?

Yes. 5082-H14 has a typical yield strength of 260 MPa (37.7 ksi) against 125 MPa (18.1 ksi) for 5082-O — about 108% more. Tensile strength is 330 MPa (47.9 ksi) vs 265 MPa (38.4 ksi).

Which condition does FabDigit quote by default, H14 or O?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

Which is easier to machine, 5082-H14 or 5082-O?

5082-H14. Its machinability rates good (55/100) against fair (40/100) for 5082-O; for welding the order is 5082-O first (excellent, 90/100) then 5082-H14 (excellent, 85/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 5082-H14 and 5082-O side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.