FabDigitFabDigit

Aluminum 5082-H32 vs 5082-O

Aluminum · 5082 temper comparison

5082-H32 and 5082-O are two conditions of the same aluminum grade, 5082: H32 (strain hardened and stabilized, quarter hard) versus O (annealed). The chemistry is identical, so every difference below comes from the condition. 5082-H32 is the stronger of the two: yield strength 215 MPa (31.2 ksi) against 125 MPa (18.1 ksi) for 5082-O, about 72% more; tensile strength follows at 305 MPa (44.2 ksi) vs 265 MPa (38.4 ksi). In exchange, 5082-O is the more ductile: elongation 24% versus 12% for 5082-H32, and 5082-H32 is harder (76 HB vs 62 HB). On the shop floor, 5082-H32 machines more easily (50 vs 40 out of 100).

5082-H32Choose it when strength drives the design, or when the part is machined in volume.

5082-OChoose it when the part is bent, formed or impact-loaded.

5082-H32 vs 5082-O: properties

5082-H325082-O

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

305 MPa44.2 ksi
265 MPa38.4 ksi

Yield Strength (0.2% offset)

215 MPa31.2 ksi
125 MPa18.1 ksi

Elongation at Break

12%
24%

Shear Strength

185 MPa26.8 ksi
165 MPa23.9 ksi

Fatigue Strength (Endurance Limit)

150 MPa21.8 ksi
135 MPa19.6 ksi

Fracture Toughness (K_IC)

32 MPa·√m29.1 ksi·√in
40 MPa·√m36.4 ksi·√in

Hardness, Brinell

76 HB
62 HB

Same in both: Elastic (Young's) Modulus 70 GPa10.2 Msi · Shear Modulus 26.4 GPa3.8 Msi · Bulk Modulus 69 GPa10 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.65 g/cm³0.1 lb/in³ · Melting Point (Solidus) 577°C1,071 °F · Liquidus Temperature 638°C1,180 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

118 W/m·K68.2 BTU/hr·ft·°F
123 W/m·K71.1 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 24.2 µm/m·K13.4 µin/in·°F · Latent Heat of Fusion 395 J/g170 BTU/lb · Max Service Temperature (continuous) 65°C149 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

29 % IACS
29.5 % IACS

Electrical Resistivity

5.9×10⁻⁸ Ω·m2.32 µΩ·in
5.85×10⁻⁸ Ω·m2.3 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

77 / 100
76 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.87 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

50 / 100
40 / 100

Machinability Rating (AISI 1212 = 100 %)

33%
25%

Weldability

87 / 100
90 / 100

Formability (cold)

70 / 100
92 / 100

Same in both: Brazeability / Solderability 20 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,100 L/kg132 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale5082

5082-H32 vs 5082-O — frequently asked

Is 5082-H32 stronger than 5082-O?

Yes. 5082-H32 has a typical yield strength of 215 MPa (31.2 ksi) against 125 MPa (18.1 ksi) for 5082-O — about 72% more. Tensile strength is 305 MPa (44.2 ksi) vs 265 MPa (38.4 ksi).

Which condition does FabDigit quote by default, H32 or O?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

Which is easier to machine, 5082-H32 or 5082-O?

5082-H32, by a small margin. Both rate fair for machinability — 50/100 against 40/100 for 5082-O.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 5082-H32 and 5082-O side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.