FabDigitFabDigit

Aluminum 5082-H111 vs 5082-H14

Aluminum · 5082 temper comparison

5082-H111 and 5082-H14 are two conditions of the same aluminum grade, 5082: H111 (slightly strain hardened) versus H14 (strain hardened, half hard). The chemistry is identical, so every difference below comes from the condition. 5082-H14 is the stronger of the two: yield strength 260 MPa (37.7 ksi) against 140 MPa (20.3 ksi) for 5082-H111, about 86% more; tensile strength follows at 330 MPa (47.9 ksi) vs 275 MPa (39.9 ksi). In exchange, 5082-H111 is the more ductile: elongation 20% versus 9% for 5082-H14, and 5082-H14 is harder (85 HB vs 66 HB). On the shop floor, 5082-H14 machines more easily (good vs fair).

5082-H111Choose it when the part is bent, formed or impact-loaded.

5082-H14Choose it when strength drives the design, or when the part is machined in volume.

5082-H111 vs 5082-H14: properties

5082-H1115082-H14

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

275 MPa39.9 ksi
330 MPa47.9 ksi

Yield Strength (0.2% offset)

140 MPa20.3 ksi
260 MPa37.7 ksi

Elongation at Break

20%
9%

Shear Strength

170 MPa24.7 ksi
195 MPa28.3 ksi

Fatigue Strength (Endurance Limit)

140 MPa20.3 ksi
155 MPa22.5 ksi

Fracture Toughness (K_IC)

36 MPa·√m32.8 ksi·√in
28 MPa·√m25.5 ksi·√in

Hardness, Brinell

66 HB
85 HB

Same in both: Elastic (Young's) Modulus 70 GPa10.2 Msi · Shear Modulus 26.4 GPa3.8 Msi · Bulk Modulus 69 GPa10 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.65 g/cm³0.1 lb/in³ · Melting Point (Solidus) 577°C1,071 °F · Liquidus Temperature 638°C1,180 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

120 W/m·K69.3 BTU/hr·ft·°F
117 W/m·K67.6 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 24.2 µm/m·K13.4 µin/in·°F · Latent Heat of Fusion 395 J/g170 BTU/lb · Max Service Temperature (continuous) 65°C149 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 29 % IACS · Electrical Resistivity 5.9×10⁻⁸ Ω·m2.32 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

74 / 100
70 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.87 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

45 / 100
55 / 100

Machinability Rating (AISI 1212 = 100 %)

30%
37%

Weldability

88 / 100
85 / 100

Formability (cold)

85 / 100
58 / 100

Same in both: Brazeability / Solderability 20 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,100 L/kg132 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale5082

5082-H111 vs 5082-H14 — frequently asked

Is 5082-H14 stronger than 5082-H111?

Yes. 5082-H14 has a typical yield strength of 260 MPa (37.7 ksi) against 140 MPa (20.3 ksi) for 5082-H111 — about 86% more. Tensile strength is 330 MPa (47.9 ksi) vs 275 MPa (39.9 ksi).

Which condition does FabDigit quote by default, H111 or H14?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

Which is easier to machine, 5082-H111 or 5082-H14?

5082-H14. Its machinability rates good (55/100) against fair (45/100) for 5082-H111.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 5082-H111 and 5082-H14 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.