FabDigitFabDigit

Aluminum 5050-H112 vs 5050-H14

Aluminum · 5050 temper comparison

5050-H112 and 5050-H14 are two conditions of the same aluminum grade, 5050: H112 (strain hardened from hot working only) versus H14 (strain hardened, half hard). The chemistry is identical, so every difference below comes from the condition. 5050-H14 is the stronger of the two: yield strength 165 MPa (23.9 ksi) against 70 MPa (10.2 ksi) for 5050-H112, about 136% more; tensile strength follows at 195 MPa (28.3 ksi) vs 150 MPa (21.8 ksi). In exchange, 5050-H112 is the more ductile: elongation 20% versus 6% for 5050-H14, and 5050-H14 is harder (53 HB vs 38 HB). 5050-H112 runs hotter in service (200°C vs 120°C continuous).

5050-H112Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

5050-H14Choose it when strength drives the design.

5050-H112 vs 5050-H14: properties

5050-H1125050-H14

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

150 MPa21.8 ksi
195 MPa28.3 ksi

Yield Strength (0.2% offset)

70 MPa10.2 ksi
165 MPa23.9 ksi

Elongation at Break

20%
6%

Shear Strength

100 MPa14.5 ksi
125 MPa18.1 ksi

Fatigue Strength (Endurance Limit)

83 MPa12 ksi
90 MPa13.1 ksi

Hardness, Brinell

38 HB
53 HB

Same in both: Elastic (Young's) Modulus 68.9 GPa10 Msi · Shear Modulus 25.9 GPa3.8 Msi · Bulk Modulus 75 GPa10.9 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.69 g/cm³0.1 lb/in³ · Melting Point (Solidus) 627°C1,161 °F · Liquidus Temperature 652°C1,206 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

193 W/m·K112 BTU/hr·ft·°F
191 W/m·K110 BTU/hr·ft·°F

Max Service Temperature (continuous)

200°C392 °F
120°C248 °F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.8 µm/m·K13.2 µin/in·°F · Latent Heat of Fusion 397 J/g171 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

50.5 % IACS
50 % IACS

Electrical Resistivity

3.42×10⁻⁸ Ω·m1.35 µΩ·in
3.45×10⁻⁸ Ω·m1.36 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

78 / 100
76 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.83 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

33 / 100
40 / 100

Machinability Rating (AISI 1212 = 100 %)

25%
40%

Weldability

88 / 100
85 / 100

Formability (cold)

90 / 100
60 / 100

Polishability

70 / 100
88 / 100

Same in both: Brazeability / Solderability 35 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale5050

5050-H112 vs 5050-H14 — frequently asked

Is 5050-H14 stronger than 5050-H112?

Yes. 5050-H14 has a typical yield strength of 165 MPa (23.9 ksi) against 70 MPa (10.2 ksi) for 5050-H112 — about 136% more. Tensile strength is 195 MPa (28.3 ksi) vs 150 MPa (21.8 ksi).

Which condition does FabDigit quote by default, H112 or H14?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

Which is easier to machine, 5050-H112 or 5050-H14?

5050-H14. Its machinability rates fair (40/100) against poor (33/100) for 5050-H112.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 5050-H112 and 5050-H14 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.