FabDigitFabDigit

Aluminum 5050-H112 vs 5050-H32

Aluminum · 5050 temper comparison

5050-H112 and 5050-H32 are two conditions of the same aluminum grade, 5050: H112 (strain hardened from hot working only) versus H32 (strain hardened and stabilized, quarter hard). The chemistry is identical, so every difference below comes from the condition. 5050-H32 is the stronger of the two: yield strength 145 MPa (21 ksi) against 70 MPa (10.2 ksi) for 5050-H112, about 107% more; tensile strength follows at 170 MPa (24.7 ksi) vs 150 MPa (21.8 ksi). In exchange, 5050-H112 is the more ductile: elongation 20% versus 9% for 5050-H32, and 5050-H32 is harder (46 HB vs 38 HB). 5050-H112 runs hotter in service (200°C vs 150°C continuous).

5050-H112Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

5050-H32Choose it when strength drives the design.

5050-H112 vs 5050-H32: properties

5050-H1125050-H32

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

150 MPa21.8 ksi
170 MPa24.7 ksi

Yield Strength (0.2% offset)

70 MPa10.2 ksi
145 MPa21 ksi

Elongation at Break

20%
9%

Shear Strength

100 MPa14.5 ksi
115 MPa16.7 ksi

Fatigue Strength (Endurance Limit)

83 MPa12 ksi
90 MPa13.1 ksi

Hardness, Brinell

38 HB
46 HB

Same in both: Elastic (Young's) Modulus 68.9 GPa10 Msi · Shear Modulus 25.9 GPa3.8 Msi · Bulk Modulus 75 GPa10.9 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.69 g/cm³0.1 lb/in³ · Melting Point (Solidus) 627°C1,161 °F · Liquidus Temperature 652°C1,206 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

193 W/m·K112 BTU/hr·ft·°F
191 W/m·K110 BTU/hr·ft·°F

Max Service Temperature (continuous)

200°C392 °F
150°C302 °F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.8 µm/m·K13.2 µin/in·°F · Latent Heat of Fusion 397 J/g171 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

50.5 % IACS
50 % IACS

Electrical Resistivity

3.42×10⁻⁸ Ω·m1.35 µΩ·in
3.45×10⁻⁸ Ω·m1.36 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

78 / 100
75 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.83 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

33 / 100
40 / 100

Machinability Rating (AISI 1212 = 100 %)

25%
30%

Weldability

88 / 100
85 / 100

Formability (cold)

90 / 100
80 / 100

Same in both: Brazeability / Solderability 35 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale5050

5050-H112 vs 5050-H32 — frequently asked

Is 5050-H32 stronger than 5050-H112?

Yes. 5050-H32 has a typical yield strength of 145 MPa (21 ksi) against 70 MPa (10.2 ksi) for 5050-H112 — about 107% more. Tensile strength is 170 MPa (24.7 ksi) vs 150 MPa (21.8 ksi).

Which condition does FabDigit quote by default, H112 or H32?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

Which is easier to machine, 5050-H112 or 5050-H32?

5050-H32. Its machinability rates fair (40/100) against poor (33/100) for 5050-H112.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 5050-H112 and 5050-H32 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.