FabDigitFabDigit

Aluminum 5050-H111 vs 5050-H14

Aluminum · 5050 temper comparison

5050-H111 and 5050-H14 are two conditions of the same aluminum grade, 5050: H111 (slightly strain hardened) versus H14 (strain hardened, half hard). The chemistry is identical, so every difference below comes from the condition. 5050-H14 is the stronger of the two: yield strength 165 MPa (23.9 ksi) against 65 MPa (9.43 ksi) for 5050-H111, about 154% more; tensile strength follows at 195 MPa (28.3 ksi) vs 150 MPa (21.8 ksi). In exchange, 5050-H111 is the more ductile: elongation 20% versus 6% for 5050-H14, and 5050-H14 is harder (53 HB vs 37 HB). 5050-H111 runs hotter in service (150°C vs 120°C continuous). On the shop floor, 5050-H14 machines more easily (fair vs poor).

5050-H111Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

5050-H14Choose it when strength drives the design, or when the part is machined in volume.

5050-H111 vs 5050-H14: properties

5050-H1115050-H14

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Bulk Modulus

68 GPa9.9 Msi
75 GPa10.9 Msi

Tensile Strength (Ultimate)

150 MPa21.8 ksi
195 MPa28.3 ksi

Yield Strength (0.2% offset)

65 MPa9.4 ksi
165 MPa23.9 ksi

Elongation at Break

20%
6%

Shear Strength

105 MPa15.2 ksi
125 MPa18.1 ksi

Fatigue Strength (Endurance Limit)

85 MPa12.3 ksi
90 MPa13.1 ksi

Hardness, Brinell

37 HB
53 HB

Same in both: Elastic (Young's) Modulus 68.9 GPa10 Msi · Shear Modulus 25.9 GPa3.8 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.69 g/cm³0.1 lb/in³ · Melting Point (Solidus) 627°C1,161 °F · Liquidus Temperature 652°C1,206 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

193 W/m·K112 BTU/hr·ft·°F
191 W/m·K110 BTU/hr·ft·°F

Max Service Temperature (continuous)

150°C302 °F
120°C248 °F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.8 µm/m·K13.2 µin/in·°F · Latent Heat of Fusion 397 J/g171 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 50 % IACS · Electrical Resistivity 3.45×10⁻⁸ Ω·m1.36 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.83 V · Corrosion Resistance 76 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

30 / 100
40 / 100

Machinability Rating (AISI 1212 = 100 %)

30%
40%

Formability (cold)

90 / 100
60 / 100

Brazeability / Solderability

40 / 100
35 / 100

Polishability

85 / 100
88 / 100

Same in both: Weldability 85 / 100

Sustainability

Primary-production footprint per kilogram.

Embodied Water

1,150 L/kg138 gal/lb
1,200 L/kg144 gal/lb

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12 kg CO₂/kg · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale5050

5050-H111 vs 5050-H14 — frequently asked

Is 5050-H14 stronger than 5050-H111?

Yes. 5050-H14 has a typical yield strength of 165 MPa (23.9 ksi) against 65 MPa (9.43 ksi) for 5050-H111 — about 154% more. Tensile strength is 195 MPa (28.3 ksi) vs 150 MPa (21.8 ksi).

Which condition does FabDigit quote by default, H111 or H14?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

Which is easier to machine, 5050-H111 or 5050-H14?

5050-H14. Its machinability rates fair (40/100) against poor (30/100) for 5050-H111.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 5050-H111 and 5050-H14 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.