FabDigitFabDigit

Aluminum 5005A vs 5050

Aluminum · grade comparison

Aluminum 5005A and 5050 are both aluminum grades. 5050 is the stronger of the two: tensile strength 170 MPa (24.7 ksi) against 160 MPa (23.2 ksi) for 5005A, about 6% more. 5050 is the more ductile: elongation 9% versus 6% for 5005A, and 5050 is harder (46 HB vs 41 HB). On the shop floor, 5050 sits in a lower cost tier (budget, $) than 5005A (standard, $$).

5050Choose it when strength drives the design, or when the part is bent, formed or impact-loaded.

5005A vs 5050: properties

5005A5050

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

69.5 GPa10.1 Msi
68.9 GPa10 Msi

Shear Modulus

26 GPa3.8 Msi
25.9 GPa3.8 Msi

Bulk Modulus

68 GPa9.9 Msi
75 GPa10.9 Msi

Tensile Strength (Ultimate)

160 MPa23.2 ksi
170 MPa24.7 ksi

Yield Strength (0.2% offset)

150 MPa21.8 ksi
145 MPa21 ksi

Elongation at Break

6%
9%

Shear Strength

97 MPa14.1 ksi
115 MPa16.7 ksi

Fatigue Strength (Endurance Limit)

62 MPa9 ksi
90 MPa13.1 ksi

Hardness, Brinell

41 HB
46 HB

Hardness, Vickers

45 HV
—

Same in both: Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Melting Point (Solidus)

632°C1,170 °F
627°C1,161 °F

Liquidus Temperature

654°C1,209 °F
652°C1,206 °F

Same in both: Density 2.69 g/cm³0.1 lb/in³

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

200 W/m·K116 BTU/hr·ft·°F
191 W/m·K110 BTU/hr·ft·°F

Thermal Expansion (CTE, 20–100 °C)

23.7 µm/m·K13.2 µin/in·°F
23.8 µm/m·K13.2 µin/in·°F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Latent Heat of Fusion 397 J/g171 BTU/lb · Max Service Temperature (continuous) 150°C302 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

52 % IACS
50 % IACS

Electrical Resistivity

3.32×10⁻⁸ Ω·m1.31 µΩ·in
3.45×10⁻⁸ Ω·m1.36 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

72 / 100
75 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.83 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability Rating (AISI 1212 = 100 %)

40%
30%

Weldability

88 / 100
85 / 100

Formability (cold)

70 / 100
80 / 100

Castability

30 / 100
—

Polishability

75 / 100
70 / 100

Same in both: Machinability 40 / 100 · Brazeability / Solderability 35 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 35%

Common Calculations

Ratios derived from the values above.

Specific Strength (UTS / density)

59 kN·m/kg
63 kN·m/kg

Specific Stiffness (E / density)

25.8 MN·m/kg
25.6 MN·m/kg

Modulus of Resilience

162 kJ/m³
153 kJ/m³

Thermal Diffusivity

82.6 mm²/s
78.9 mm²/s

Thermal Shock Resistance Index

19
20

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale50505005A

Manufacturing and finishing

Capability5005A5050
CNC machining—Yes
Sheet metal—Yes
Default condition——
Relative cost$$ Standard$ Budget
Min. machined wall—0.5 mm
Best machined surface—Ra 0.8 µm
Anodizing Type II—Yes
Cerakote—Yes
Chem Film (Alodine)—Yes
DLC—Yes
E-Coating—Yes
Electropolishing—Yes
Hard Anodize Type III w/ PTFE—Yes
Hard Anodizing Type III—Yes
Nickel Plating—Yes
PTFE Coating—Yes
Painting—Yes
Powder Coating—Yes

They share 4 finishes: Electroless Nickel (EN), Epoxy Coating, Gold Plating, Silver Plating.

5005A vs 5050 — frequently asked

Is 5050 stronger than 5005A?

Yes. 5050 has a typical tensile strength of 170 MPa (24.7 ksi) against 160 MPa (23.2 ksi) for 5005A — about 6% more.

Which is cheaper, 5005A or 5050?

5050 is the lower-cost material: it sits in the budget tier ($) while 5005A is standard ($$). Part price depends far more on geometry, tolerance and quantity than on raw stock — upload a CAD file for a live quote.

When should I choose 5005A over 5050?

Pick 5050 when strength drives the design, or when the part is bent, formed or impact-loaded.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 5005A and 5050 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.