Aluminum 356-T6 vs 356-T7

Aluminum · 356 temper comparison

356-T6 and 356-T7 are two conditions of the same aluminum grade, 356: T6 (solution heat treated and artificially aged) versus T7 (solution heat treated and overaged (stabilized)). The chemistry is identical, so every difference below comes from the condition. 356-T7 is the stronger of the two: yield strength 207 MPa (30 ksi) against 186 MPa (27 ksi) for 356-T6, about 11% more. In exchange, 356-T6 is the more ductile: elongation 5% versus 2% for 356-T7, and 356-T6 is harder (80 HB vs 75 HB). 356-T7 runs hotter in service (200°C vs 150°C continuous).

356-T6Choose it when the part is bent, formed or impact-loaded.

356-T7Choose it when strength drives the design, or when the part sees heat.

356-T6 vs 356-T7: properties

356-T6356-T7

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

262 MPa38 ksi
234 MPa33.9 ksi

Yield Strength (0.2% offset)

186 MPa27 ksi
207 MPa30 ksi

Elongation at Break

5%
2%

Shear Strength

179 MPa26 ksi
172 MPa24.9 ksi

Fatigue Strength (Endurance Limit)

90 MPa13.1 ksi
76 MPa11 ksi

Hardness, Brinell

80 HB
75 HB

Same in both: Elastic (Young's) Modulus 72.4 GPa10.5 Msi · Shear Modulus 27 GPa3.9 Msi · Bulk Modulus 71 GPa10.3 Msi · Poisson's Ratio 0.33 · Compressive Strength 190 MPa27.6 ksi · Fracture Toughness (K_IC) 20 MPa·√m18.2 ksi·√in · Charpy V-Notch Impact (RT) 5 J3.7 ft·lbf

Physical

Density and transition temperatures.

Same in both: Density 2.67 g/cm³0.1 lb/in³ · Melting Point (Solidus) 557°C1,035 °F · Liquidus Temperature 613°C1,135 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

151 W/m·K87.2 BTU/hr·ft·°F
155 W/m·K89.6 BTU/hr·ft·°F

Max Service Temperature (continuous)

150°C302 °F
200°C392 °F

Same in both: Specific Heat Capacity 963 J/kg·K0.23 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 21.5 µm/m·K11.9 µin/in·°F · Latent Heat of Fusion 389 J/g167 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

39 % IACS
40 % IACS

Same in both: Electrical Resistivity 4.4×10⁻⁸ Ω·m1.73 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.83 V · Corrosion Resistance 62 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

70 / 100
68 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 120% · Weldability 78 / 100 · Formability (cold) 10 / 100 · Castability 95 / 100 · Brazeability / Solderability 30 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 60%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale356

356-T6 vs 356-T7 — frequently asked

Is 356-T7 stronger than 356-T6?

Yes. 356-T7 has a typical yield strength of 207 MPa (30 ksi) against 186 MPa (27 ksi) for 356-T6 — about 11% more. Tensile strength is 234 MPa (33.9 ksi) vs 262 MPa (38 ksi).

Which condition does FabDigit quote by default, T6 or T7?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

When should I choose 356-T6 over 356-T7?

Pick 356-T6 when the part is bent, formed or impact-loaded. Pick 356-T7 when strength drives the design, or when the part sees heat.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 356-T6 and 356-T7 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.