3105-H14 and 3105-O are two conditions of the same aluminum grade, 3105: H14 (strain hardened, half hard) versus O (annealed). The chemistry is identical, so every difference below comes from the condition. 3105-H14 is the stronger of the two: yield strength 150 MPa (21.8 ksi) against 55 MPa (7.98 ksi) for 3105-O, about 173% more; tensile strength follows at 170 MPa (24.7 ksi) vs 115 MPa (16.7 ksi). In exchange, 3105-O is the more ductile: elongation 24% versus 5% for 3105-H14, and 3105-H14 is harder (46 HB vs 28 HB). 3105-O runs hotter in service (200°C vs 150°C continuous). On the shop floor, 3105-H14 machines more easily (fair vs poor).

3105-H14Choose it when strength drives the design, or when the part is machined in volume.

3105-OChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

3105-H14 vs 3105-O: properties

3105-H143105-O

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

170 MPa24.7 ksi
115 MPa16.7 ksi

Yield Strength (0.2% offset)

150 MPa21.8 ksi
55 MPa8 ksi

Elongation at Break

5%
24%

Shear Strength

105 MPa15.2 ksi
83 MPa12 ksi

Fatigue Strength (Endurance Limit)

60 MPa8.7 ksi
62 MPa9 ksi

Hardness, Brinell

46 HB
28 HB

Same in both: Elastic (Young's) Modulus 69 GPa10 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 69 GPa10 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.72 g/cm³0.1 lb/in³ · Melting Point (Solidus) 635°C1,175 °F · Liquidus Temperature 655°C1,211 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

173 W/m·K100 BTU/hr·ft·°F
180 W/m·K104 BTU/hr·ft·°F

Max Service Temperature (continuous)

150°C302 °F
200°C392 °F

Same in both: Specific Heat Capacity 897 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.6 µm/m·K13.1 µin/in·°F · Latent Heat of Fusion 393 J/g169 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

41 % IACS
43 % IACS

Same in both: Electrical Resistivity 4.2×10⁻⁸ Ω·m1.65 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.83 V · Corrosion Resistance 68 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

44 / 100
30 / 100

Formability (cold)

68 / 100
95 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 35% · Weldability 85 / 100 · Brazeability / Solderability 60 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale3105

3105-H14 vs 3105-O — frequently asked

Is 3105-H14 stronger than 3105-O?

Yes. 3105-H14 has a typical yield strength of 150 MPa (21.8 ksi) against 55 MPa (7.98 ksi) for 3105-O — about 173% more. Tensile strength is 170 MPa (24.7 ksi) vs 115 MPa (16.7 ksi).

Which condition does FabDigit quote by default, H14 or O?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

Which is easier to machine, 3105-H14 or 3105-O?

3105-H14. Its machinability rates fair (44/100) against poor (30/100) for 3105-O.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 3105-H14 and 3105-O side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.