FabDigitFabDigit

Aluminum 1200-H111 vs 1200-O

Aluminum · 1200 temper comparison

1200-H111 and 1200-O are two conditions of the same aluminum grade, 1200: H111 (slightly strain hardened) versus O (annealed). The chemistry is identical, so every difference below comes from the condition. 1200-H111 is the stronger of the two: yield strength 35 MPa (5.08 ksi) against 32 MPa (4.64 ksi) for 1200-O, about 9% more; tensile strength follows at 95 MPa (13.8 ksi) vs 90 MPa (13.1 ksi). In exchange, 1200-O is the more ductile: elongation 40% versus 32% for 1200-H111.

1200-H111Choose it when strength drives the design.

1200-OChoose it when the part is bent, formed or impact-loaded.

1200-H111 vs 1200-O: properties

1200-H1111200-O

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

95 MPa13.8 ksi
90 MPa13.1 ksi

Yield Strength (0.2% offset)

35 MPa5.1 ksi
32 MPa4.6 ksi

Elongation at Break

32%
40%

Hardness, Brinell

24 HB
23 HB

Same in both: Elastic (Young's) Modulus 69 GPa10 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 70 GPa10.2 Msi · Poisson's Ratio 0.33 · Shear Strength 62 MPa9 ksi · Fatigue Strength (Endurance Limit) 34 MPa4.9 ksi

Physical

Density and transition temperatures.

Same in both: Density 2.71 g/cm³0.1 lb/in³ · Melting Point (Solidus) 645°C1,193 °F · Liquidus Temperature 657°C1,215 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

231 W/m·K133 BTU/hr·ft·°F
230 W/m·K133 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.4 µm/m·K13 µin/in·°F · Latent Heat of Fusion 390 J/g168 BTU/lb · Max Service Temperature (continuous) 200°C392 °F · Min Service Temperature -250°C-418 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 59 % IACS · Electrical Resistivity 2.92×10⁻⁸ Ω·m1.15 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.83 V · Corrosion Resistance 72 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

30 / 100
25 / 100

Machinability Rating (AISI 1212 = 100 %)

25%
20%

Weldability

93 / 100
92 / 100

Formability (cold)

94 / 100
96 / 100

Same in both: Castability 30 / 100 · Brazeability / Solderability 80 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 20%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale1200

1200-H111 vs 1200-O — frequently asked

Is 1200-H111 stronger than 1200-O?

Yes. 1200-H111 has a typical yield strength of 35 MPa (5.08 ksi) against 32 MPa (4.64 ksi) for 1200-O — about 9% more. Tensile strength is 95 MPa (13.8 ksi) vs 90 MPa (13.1 ksi).

Which condition does FabDigit quote by default, H111 or O?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

Which is easier to machine, 1200-H111 or 1200-O?

1200-H111, by a small margin. Both rate poor for machinability — 30/100 against 25/100 for 1200-O.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1200-H111 and 1200-O side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.