FabDigitFabDigit

Aluminum 1200-H111 vs 1200-H112

Aluminum · 1200 temper comparison

1200-H111 and 1200-H112 are two conditions of the same aluminum grade, 1200: H111 (slightly strain hardened) versus H112 (strain hardened from hot working only). The chemistry is identical, so every difference below comes from the condition. 1200-H112 is the stronger of the two: yield strength 40 MPa (5.8 ksi) against 35 MPa (5.08 ksi) for 1200-H111, about 14% more. In exchange, 1200-H111 is the more ductile: elongation 32% versus 28% for 1200-H112. 1200-H111 runs hotter in service (200°C vs 150°C continuous).

1200-H111Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

1200-H112Choose it when strength drives the design.

1200-H111 vs 1200-H112: properties

1200-H1111200-H112

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

95 MPa13.8 ksi
90 MPa13.1 ksi

Yield Strength (0.2% offset)

35 MPa5.1 ksi
40 MPa5.8 ksi

Elongation at Break

32%
28%

Shear Strength

62 MPa9 ksi
60 MPa8.7 ksi

Same in both: Elastic (Young's) Modulus 69 GPa10 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 70 GPa10.2 Msi · Poisson's Ratio 0.33 · Fatigue Strength (Endurance Limit) 34 MPa4.9 ksi · Hardness, Brinell 24 HB

Physical

Density and transition temperatures.

Same in both: Density 2.71 g/cm³0.1 lb/in³ · Melting Point (Solidus) 645°C1,193 °F · Liquidus Temperature 657°C1,215 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

231 W/m·K133 BTU/hr·ft·°F
224 W/m·K129 BTU/hr·ft·°F

Thermal Expansion (CTE, 20–100 °C)

23.4 µm/m·K13 µin/in·°F
23.6 µm/m·K13.1 µin/in·°F

Latent Heat of Fusion

390 J/g168 BTU/lb
397 J/g171 BTU/lb

Max Service Temperature (continuous)

200°C392 °F
150°C302 °F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Min Service Temperature -250°C-418 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

59 % IACS
58 % IACS

Electrical Resistivity

2.92×10⁻⁸ Ω·m1.15 µΩ·in
2.97×10⁻⁸ Ω·m1.17 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.83 V · Corrosion Resistance 72 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

30 / 100
32 / 100

Machinability Rating (AISI 1212 = 100 %)

25%
30%

Weldability

93 / 100
92 / 100

Formability (cold)

94 / 100
92 / 100

Polishability

70 / 100
75 / 100

Same in both: Castability 30 / 100 · Brazeability / Solderability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Embodied Energy (primary production)

200 MJ/kg85,985 BTU/lb
205 MJ/kg88,134 BTU/lb

Embodied Carbon (primary production)

12 kg CO₂/kg
12.5 kg CO₂/kg

Typical Recycled Content

20%
30%

Same in both: Embodied Water 1,200 L/kg144 gal/lb

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale1200

1200-H111 vs 1200-H112 — frequently asked

Is 1200-H112 stronger than 1200-H111?

Yes. 1200-H112 has a typical yield strength of 40 MPa (5.8 ksi) against 35 MPa (5.08 ksi) for 1200-H111 — about 14% more. Tensile strength is 90 MPa (13.1 ksi) vs 95 MPa (13.8 ksi).

Which condition does FabDigit quote by default, H111 or H112?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

When should I choose 1200-H111 over 1200-H112?

Pick 1200-H111 when the part is bent, formed or impact-loaded, or when the part sees heat. Pick 1200-H112 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1200-H111 and 1200-H112 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.