FabDigitFabDigit

Aluminum 1060-H112 vs 1060-O

Aluminum · 1060 temper comparison

1060-H112 and 1060-O are two conditions of the same aluminum grade, 1060: H112 (strain hardened from hot working only) versus O (annealed). The chemistry is identical, so every difference below comes from the condition. 1060-H112 is the stronger of the two: yield strength 35 MPa (5.08 ksi) against 28 MPa (4.06 ksi) for 1060-O, about 25% more; tensile strength follows at 78 MPa (11.3 ksi) vs 70 MPa (10.2 ksi). In exchange, 1060-O is the more ductile: elongation 43% versus 25% for 1060-H112, and 1060-H112 is harder (21 HB vs 19 HB).

1060-H112Choose it when strength drives the design.

1060-OChoose it when the part is bent, formed or impact-loaded.

1060-H112 vs 1060-O: properties

1060-H1121060-O

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

78 MPa11.3 ksi
70 MPa10.2 ksi

Yield Strength (0.2% offset)

35 MPa5.1 ksi
28 MPa4.1 ksi

Elongation at Break

25%
43%

Shear Strength

52 MPa7.5 ksi
48 MPa7 ksi

Fatigue Strength (Endurance Limit)

24 MPa3.5 ksi
20 MPa2.9 ksi

Hardness, Brinell

21 HB
19 HB

Hardness, Vickers

23 HV
21 HV

Same in both: Elastic (Young's) Modulus 69 GPa10 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 68 GPa9.9 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.71 g/cm³0.1 lb/in³ · Melting Point (Solidus) 646°C1,195 °F · Liquidus Temperature 657°C1,215 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 234 W/m·K135 BTU/hr·ft·°F · Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.6 µm/m·K13.1 µin/in·°F · Latent Heat of Fusion 397 J/g171 BTU/lb · Max Service Temperature (continuous) 200°C392 °F · Min Service Temperature -269°C-452 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 62 % IACS · Electrical Resistivity 2.78×10⁻⁸ Ω·m1.09 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.84 V · Corrosion Resistance 72 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

33 / 100
25 / 100

Formability (cold)

90 / 100
98 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 30% · Weldability 95 / 100 · Brazeability / Solderability 70 / 100 · Polishability 88 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 205 MJ/kg88,134 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 20%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale1060

1060-H112 vs 1060-O — frequently asked

Is 1060-H112 stronger than 1060-O?

Yes. 1060-H112 has a typical yield strength of 35 MPa (5.08 ksi) against 28 MPa (4.06 ksi) for 1060-O — about 25% more. Tensile strength is 78 MPa (11.3 ksi) vs 70 MPa (10.2 ksi).

Which condition does FabDigit quote by default, H112 or O?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

Which is easier to machine, 1060-H112 or 1060-O?

1060-H112, by a small margin. Both rate poor for machinability — 33/100 against 25/100 for 1060-O.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 1060-H112 and 1060-O side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.